The Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook** but will hopefully provide some help in navigating, while reading the code. The 24th Edition of the CE-C, Part I, (C22.1-18)* is now available from CSA Group.

In this article: diagrams and appendices. The Diagrams section of the Code contains 10 diagrams that illustrate essential information referenced by various rules of the Code. Diagrams referenced by rules are considered normative (mandatory) elements of the Code.

Diagram 1, which is referenced by Rules 26-700, 26-720, 26-744, 38-023, 58-400, 78-052, 78-102, and 86-306, as well as Diagram 2 and Appendix B, provides face illustrations for the CSA configurations for non-locking receptacles based on nominal voltages and amperages.


Diagram 2, which is referenced by Rules 12-020, 26-700, 78-052, 78-102, and 86-306, as well as Diagram 1 and Appendix B, provides face illustrations for the CSA configurations for locking receptacles based on nominal voltages and amperages.

Diagram 3, which is referenced by Rule 14-102 and Appendix B, illustrates the ultimate point of conductor de-energization of a faulted circuit, downstream from the point or points marked with an asterisk.

Diagram 4, referenced by Rule 20-302 (2), illustrates the extent of the Zone 2 hazardous location from the open face of a paint spray booth.

Diagram 5, referenced by Rule 20-302, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for spraying operations not conducted in spray booths.

Diagram 6, referenced by Rule 20-302 (7), illustrates the extent of the Zone 1 and Zone 2 hazardous locations for spraying operations not conducted in spray booths, but with the ventilation system interlocked with the spraying equipment.


Diagram 7, which is referenced by Rule 20-034 and Part B of Table 63, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for tank vehicle and tank car loading and unloading.


Diagram 8, which is referenced by Rule 20-034 and Part E of Table 63, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for pumps, vapour compressors, gas-air mixers, and vapourizers outdoors, in open air.

Diagram 9, which is referenced by Rule 20-034 and Part J of Table 63, illustrates the extent of the Zone 1 and Zone 2 hazardous locations for container filling outdoors in open air.

Diagram 10, which is referenced by Rule 20-302 (3), illustrates the extent of the Zone 2 hazardous locations adjacent to openings in a closed spray booth or room.


The Appendices section of the Code contains both normative (mandatory) and informative (non-mandatory) appendices providing information associated with rules of the Code.


Appendix A - Safety Standards for Electrical Equipment is a normative section and lists the standards used to certify electrical equipment for the purpose of being “approved” as defined in Section 0. Note that adopted international standards listed in this appendix may include Canadian deviations, and compliance with them is required for implementation in Canada. Also note that CSA and other accredited standards development organizations (SDOs) may publish new Canadian standards for electrical equipment, or periodically amend or publish new editions of standards listed in this appendix, and they may be used for product approval purposes by accredited certification organizations. In accordance with the mandatory procedures in Appendix C, the SDO publishing or amending a standard must notify the project manager of the Committee on Part I for distribution to the committee.

Appendix BNotes on Rules is an informative (non-mandatory) section of the Code that provides information and illustrations clarifying various diagrams, tables and rules in the Code.


Appendix COrganization and Rules of Procedure is a normative (mandatory) section of the Code and outlines the structure of the Canadian Electrical Code, Part I Committee, sub-committees, Executive Committee and the Regulatory Authority Committee, as well as the operating procedures for developing the code. It includes:

• procedures for amendments to the Code, interpretations of the Code, and appeals, if procedures are not followed
• the format and Rule terminology of the Code
• procedures for inclusion of reference standards to Appendix A as noted above, a flow chart, and a declaration checklist
• a standard form for subcommittee reports
• a form to be used to request an amendment to the Canadian Electrical Code, Part I
• a guide to subcommittee chairs for evaluation of proposals and subcommittee reports


Appendix D - Tabulated general information is an informative (non-mandatory) section that provides 17 tables and 4 diagrams of tabulated general information.


Appendix E - Dust-free rooms is an informative (non-mandatory) section and outlines construction of dust-free rooms built adjacent to or as part of buildings that, by the nature of their use or occupancy, are subject to accumulations of dusts that may create a fire or explosion hazard, and allows you to supplant the requirements of Appendix J for Class II and Class III hazardous locations.


Appendix F - Engineering guidelines is an informative (non-mandatory) section and provides engineering guidelines for preparing descriptive system documents for intrinsically safe electrical systems and non-incendive field wiring circuits as referenced by Rules 18-002, 18-064, J18-002, and J18-064.

Appendix G - Electrical installations of fire protection systems is an informative (non-mandatory) section that lists requirements related to electrical installations of fire protection systems that are not governed by rules of the Canadian Electrical Code, Part I but are required by the National Building Code of Canada.


Appendix H - Combustible gas detection equipment is an informative (non-mandatory) section that lists requirements and recommendations for combustible gas detection equipment for use in explosive gas atmospheres as referenced by Rules 18-068 and J18-066.


Appendix I - Interpretations is an informative (non-mandatory) section and includes committee interpretations of the Canadian Electrical Code, Part I that have been requested in writing to the project manager of the Committee on Part I. The form of a question must be such that it can be answered by a categoric “yes” or “no”. These interpretations are based on rules in the 2015 Code, so rule numbering and content in the 2018 Code may differ from the 2015 edition.


Appendix J - Class and Division System Installations contains normative rules and informative notes to rules for additions, modifications, renovations to, or operation and maintenance of existing facilities employing the Class and Division system permitted by Rules 18-000 (3) 18-000 (4), 20-000 (2), and 20-000 (3). The rules of Annexes J18, J20, JD and JT of this appendix are normative (mandatory, and the notes and illustrations contained in Annex JB are informative (non-mandatory). Note: Annexes J18, J20, JD and JT, because of their length, will be discussed in future instalments.


Appendix K - Extract from IEC 60364-1 is an informative (non-mandatory) section that is an extraction from IEC Standard 60364-1 Chapter 13. Chapter 13 of Section 131 outlines the fundamental principles to provide for the safety of persons, livestock and property against dangers and damage that may arise in the reasonable use of electrical installations, and is quoted in the second paragraph of the Object of the Code.

Appendix L - Engineering guidelines is an informative (non-mandatory) section and provides engineering guidelines for determining hazardous area classifications in facilities where explosive atmospheres can occur, as required by Rule 18-004. This appendix can be used as a guide to classify both the zone system and the class and division system of hazardous locations.

Appendix M - Translated caution and warning markings is an informative (non-mandatory) section and provides a chart of caution and warning markings translated from English into French.

In the next instalment, we will be discussing Annex J18, of Appendix J.

* The source for this series of articles is the Canadian Electrical Code, Part I, (C22.1-18) published by CSA.

** Note the CEC Handbook is also published by CSA.

William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

 

 The radiant Collection: Smart Lighting Video Gallery 

Radiant CollectionElevate your space and upgrade your control. From the smartest dimmer switch and the fastest USB outlet, to a host of decorative wall plates, perfect for any taste, every device in the radiant® Collection aims to make life a little easier with extraordinary style.  Take comfort in the convenience of controlling your smart lighting system from any smart device to set the exact lighting you need — from anywhere.

 

 

 

 

Watch the video Here

 

Changing Scene

  • Prev
Susan Uthayakumar, country president, Schneider Electric, has been named a Women's Executive ...
ABB presented its electrification solutions that will allow customers to take full advantage of the ...
Electricity Human Resources Canada has introduced a new Board of Directors, effective as of their ...
Jacques Fiset, the new president of the EFC Quebec section, told us in a recent interview that his ...
Organised by the Hong Kong Trade Development Council (HKTDC), the twin lighting shows - the  ...
A Friday night, the end of summer, the weather is mild, and 2,500 people — customers, ...
Eaton focuses on developing personable connections in every aspect. In September, our team will be ...
During the recently held IMARK Canada 2019 meeting in Niagara Falls, executives from 14 of the ...
Valard has been selected by Wataynikaneyap Power LPto provide engineering, procurement ...
The Canadian Apprenticeship Forum-Forum Canadien sur l’Apprentissage (CAF-FCA) has announced ...

Ideal National ChampionshipThe 2019 Ideal National Championship was a highly charged, no-holds barred competition to determine the best electrician in North America, including teams from China, Australia and Mexico. Over 55,000 electrical contractors and electricians competed worldwide in 5 countries, and the cream of the crop competed at the 2019 Ideal National Championship in Orlando.

From November 7 to 9, 162 professionals and apprentices from the US and Canada were in Orlando to compete. 

 

 

Read More

 

 

 

Latest Articles

  • Prev
IDEAWORKS engages undergraduate students and hires co-op students in Mohawk’s Energy and ...
Pick up a newspaper or scan your preferred electronic newsfeed and you’ll likely see a series ...
Britech Corp, one of Canada’s largest heating cable companies has signed a formal agreement ...
Electrical enclosures serve to protect electrical devices from adverse environmental influences, ...

Michelle BraniganBy Michelle Branigan

Have you been “ghosted” yet?

No, I’m not referring to some strange Halloween game, but rather a phenomenon which is becoming increasingly prevalent in the workplace. While the term originally referred to the dating world and what happens when someone you're involved with suddenly stops making any contact, it has now entered the workplace.

 

 

Read More

 

 

Tools for the Trade

  • Prev
  IDEAL Industries has introduced Combination Drill Taps to its tool lineup. Combining the ...
  Stripping and crimping device, 100 - 240 V input voltage, for insulated ferrules with a ...
Professional all-in-one cutter/stripper for coaxial and twisted pair cables     ...
  Klein Tools' Coax Explorrer 2 tests coaxial cable and maps up to 4 locations   ...
  Ideal Industries' T-14 wire stripper s are ideal for all professionals working within the ...
  The ATS850 conveyor eliminates all types of electro static discharge requirements. ...
  Lorik Tool & Automation has the experience and ability to manufacture a variety of ...
  Ideal Industries' 26 piece insulated Journeyman kit is ideal for new electricians or for ...
  Klein Tools Deluxe Fish Rod Set comes in 19 pieces that when assembled can fish wire and ...
  BendWorks Software was designed to help electrical contractors adopt this new process ...

iQ-R Motion CPU'sThe R16MTCPU, R32MTCPU, and R64MTCPU motion CPUs are dedicated motion control processors designed to execute advanced synchronous control functions and high speed registration, independent of PLC scan time, for maximum performance. The dedicated Motion SFC language and graphical mechanical editor tool are optimized for the toughest synchronous motion applications in the world, including high speed printing presses and large converting lines.

 

 

Read More

 

Product News

  • Prev
Emerson announced the addition of a handheld puller to its Greenlee pulling lineup – the new ...
Hammond Manufacturing has announced its new 1557 family. Initially available in four plan ...
The classic TWR1 and TWR2 LED glass wall packs come with adjustable light output (ALO) technology. ...
Eaton has added a new ‘compact’ model to its class-leading MTL 937x-FB Fieldbus ...
The R16MTCPU, R32MTCPU, and R64MTCPU motion CPUs are dedicated motion control processors designed ...
The smallest robot controller in its class, the ultra-compact YRC1000micro minimizes installation ...
As part of the SICK AppSpace eco-system, the programmable SIM10xx Sensor Integration Machines offer ...
With the free, PC-based Festo Automation Suite commissioning software, getting a new drive package ...
Balluff’s inductive couplers connect up to eight discrete sensors across a small air gap, ...
The IP20 product family from Bihl+Wiedemann welcomes a new member:      

 

TWR2 LEDThe classic TWR1 and TWR2 LED glass wall packs come with adjustable light output (ALO) technology. TWR LED dials in to desired output to match the needs of any job site, and saves significant energy costs when replacing traditional metal halide sources. Its energy-efficient LEDs have an expected service life of more than 20 years, which eliminates frequent lamp and ballast replacements associated with traditional technologies. Cost effective, flexible, and always in stock - TWR LED is the choice for distributors and contractors alike.

 

 

 

Read More

 

 

SICK SIM10xxAs part of the SICK AppSpace eco-system, the programmable SIM10xx Sensor Integration Machines offer multiple sensor data acquisition and fusion processes, thereby providing space for new application solutions. The acquired data is processed and visualized for important information, for example quality control or process analysis. In addition, the IoT gateway functions enable connection from the edge to the cloud via the Internet in the context of Industry 4.0. The SIM10xx products feature a powerful processor and Ethernet interfaces for cameras and LiDAR sensors. Other sensors can be integrated via IO-Link, for instance for distance and height measuring purposes.

 

Read More

 

Peers & Profiles

  • Prev
For the second consecutive year, Paul Hannania was among the 162 professionals and apprentices to ...
Alexander Couckuyt, Director of Operations for Southwire Canada, spent the majority of his ...
Stephanie Medeiros leads ABB Canada’s Electric Vehicle Charging Infrastructure team, as well ...
Electrical Industry Canada had the pleasure of interviewing Matt Davis of Newfoundland Power, ...
An electrician by trade, Daniel Lacovetsky is the founder and President of Powertec Electric, an ...
Mike Morneau began his professional career in graphic arts after earning a Bachelor of Technology ...
AimLite offers a vast choice of lighting lines to facilitate any lighting project’s needs. ...
John Krill has been in the energy and construction industries for 35-years, now he serves as Canem ...
Ali Heighton is the Program Coordinator for IBEW Local 37 who has found success as a young ...
Flextherm was founded in 1991 by current company President, Philippe Charron. For more than 25 ...

 

Stephanie MedeirosBy Blake Marchand

Stephanie Medeiros leads ABB Canada’s Electric Vehicle Charging Infrastructure team, as well as transit bus charging in the United States and Canada. She has been with ABB in various positions for 10 years, compiling a diverse skill set that includes work all over the world.

After receiving a degree in Electrical Engineering from McGill University, Medeiros got her start in the industry out of school volunteering with the Canadian government as an electrical engineering intern, where she travelled to Peru to help improve their water treatment infrastructure. 

Read More

 

 

Copper $US Dollar price per pound

Electrical Industry News Week

This special weekly newsletter has the broadest reach of those that are involved in all aspects of the electrical industry including electrical construction and maintenance professionals and electrical specifying engineers across Canada. EIN is designed to provide electrical professionals’ insight and intelligence on those developments in the industry that effect design, specification, installation of electrical equipment. From corporate news to new technologies and insightful opinions EIN will become your first read in the electrical industry in Canada. Published weekly – every Tuesday
Kerrwil Publications

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2019 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil