CSAApr 9, 2017

By William (Bill) Burr

In this article: Section 42 — Electric welders. The CE Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook, but will hopefully provide some help in navigating the code.

Rule 42-000 Scope — states that Section 42 is a supplementary or amendatory section of the code and applies to the installation of electric welders. The CEC Handbook provides additional notes and diagrams to better explain this section. There are two main types of welders: arc and resistance welders. Arc welders use a sacrificial rod to weld the metal target material together. Resistance welders fuse the metal target material together. Arc welders are divided further into transformer and motor-generator types.

Rule 42-002 Special terminology — contains definitions for special terms that apply to section 42 that are not defined in Section 0 such as: actual primary current, duty cycle, and rated primary current. These terms will be important when calculating the ampacity of the supply conductors for welders.

Rule 42-004 Receptacles and attachment plugs — outlines that, where receptacles are installed for the plug and cord-connection of a portable welder, the ampacity rating of the overcurrent protection for the circuit can be more than the rating of the receptacle, but the receptacle must have a rating equal to or greater than the ampacity of the supply conductors for the welder. This is important because the high instantaneous inrush start-up current of the welder will exceed the branch circuit conductor ampacity. This prevents nuisance tripping.

Transformer arc welders

Rule 42-006 Supply conductors — provides the factors in determining the ampacity of supply conductors for transformer type arc welders. The ampacity depends on the duty cycle of a single welder, as in sub-rule (1) and the demand factors where a group of welders are supplied by one circuit as in sub-rule (2). The CEC Handbook contains Tables 42-1 and 42-2, which show the correlation between duty cycle and demand factor and determination of the demand factor for multiple welder installations.

Rule 42-008 Overcurrent protection for transformer arc welders — specifies the factors to be used in calculating the rating of circuit overcurrent protection per the ampacity of supply conductors and welders as in sub-rule (1). Sub-rule (2) outlines the factors in calculating the rating of the overcurrent protection for the supply conductors using Tables 1,2,3, or 4. Sub-rule (3) provides the factors in calculating the rating of the overcurrent protection for a feeder supplying a group of transformer arc welders.

Rule 42-010 Disconnecting means — requires that where there is no integral disconnect on the welder, one must be provided to disconnect the supply conductors, and it must have sufficient current rating capacity to accommodate the overcurrent protection.

Motor-generator arc welders

Rule 42-012 Conductors, protection, and control of motor-generator arc welders — specifies that the rules of Section 4 and Section 28 generally apply to the determination of supply conductor ampacity, and selection of protection and control. The CEC handbook outlines methods of calculation of duty-related demand factors through Table 42-1, 42-2 and 42-3.

Resistance welders

Rule 42-014 Supply conductors for resistance welders — provides the factors in determining the ampacity of supply conductors depending on the primary current or duty cycle of either an individual seam resistance welder or an automatically fed resistance welder. Table 42-4 in the CEC Handbook shows the relationship between duty cycle and demand factors.

Rule 42-016 Overcurrent protection — specifies the factors in determining the rating of the overcurrent protection based on the rated primary current of the welder and the allowable ampacity of the supply conductors based on Tables 1,2,3 or 4. The CEC Handbook outlines methods of calculation of duty related demand factors through Tables 42-3 and 42-4. For determining the rating of overcurrent Protection for a group of resistance welders use the factors contained in rule 42-014.

Rule 42-018 Control of resistance welders — requires that a resistance welder have a disconnecting switch or circuit breaker rated for the capacity of the supply conductors to isolate the welder from the supply circuit.

Rule 42-020 Nameplate data for resistance welders — requires data specific to the resistance welder be provided on the nameplate, including rated KVA at 50% duty cycle, maximum and minimum open-circuit secondary voltage, short circuit current, and the throat and gap setting.

In the next installment, we will be discussing Section 44 — Theatre installations

* The source for this series of articles is the Canadian Electrical Code, Part I, published by CSA

** Note the CEC Handbook is also published by CSA.

William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.


The source for this series of articles is the Canadian Electrical Code, Part I, published by CSA
William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

 

 

Changing Scene

  • Prev
CSA Group, in collaboration with the Ontario Ministry of Labour, Training and Skills Development ...
This month, IDEAL is challenging competitors to draw an Electrical Power One-Line Diagram ...
EngWorks Inc. and the Alberta Electrical Alliance have announced a strategic partnership as of May ...
David Collie, ESA’s President & CEO, signs the new Leadership Accord, proudly committed to ...
Electro-Federation Canada (EFC) represents electrical and automation manufacturers, distributors ...
Demand for electric vehicles in Canada keeps increasing; 68% of Canadians will consider ...
ESA is warning on potential electrical hazards associated with the replacement of metallic water ...
The Canadian Apprenticeship Forum (CAF-FCA) has released its latest labour market information ...
The Ontario government is introducing new measures to help tradespeople get their certification ...
MP Scott Duvall has introduced an amendment to the Income Tax Act regarding travel expenses for ...


 

ABB RoboticsABB Robotics is driving automation in the construction industry with new robotic automation solutions to address key challenges, including the need for more affordable and environmentally friendly housing and to reduce the environmental impact of construction, amidst a labor and skills shortage.

Robotic automation offers huge potential to enhance productivity, efficiency and manufacturing flexibility throughout the construction industry, including automating the fabrication of modular homes and building components off-site, robotic welding and material handling on building sites and robot 3D printing of houses and customized structures. 



Read More


 

Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion

 


 

Smart GridHarnessing Canada’s immense clean energy resources requires transformational investments to modernize our electricity grid. The Government of Canada is investing in renewable energy and upgrading the electricity grid to make clean, affordable electricity options more accessible in communities across Canada.

The Honourable Seamus O’Regan Jr., Minister of Natural Resources, today launched a $964-million program to support smart renewable energy and grid modernization projects that will lower emissions by investing in clean energy technologies, like wind, solar, storage, hydro, geothermal and tidal.

Read More

 


 



Trilliant Partners with the City of CowansvilleThe City of Cowansville in south-central Quebec is the largest city in the Brome-Missisquoi region, with more than 15,000 residents. Despite being a smaller-sized city, it is known as an economic and industrial hub.

It also has a strong focus on innovation and efficiency — as demonstrated by decisions such as the one it made in 2017 to use beet juice to help combat icy winter roads, allowing the City to reduce the amount of salt it was using, thereby saving money and decreasing the impact on the environment. 

 

 

Read More


 

Keith SonesBy Keith Sones

The writing was on the wall.  The closures would happen. But a lot of people were upset, and I was one of them. 

In the early 2000s, my family and I were living in a mainly rural (at least by city dweller standards) valley in south central British Columbia.  The West Kootenay region is known for its diverse outdoor recreation activities and as a great place to raise a family.  It has a proud industrial history, evidenced through the longstanding pulp mill, a massive lead zinc smelter a few miles away and several hydroelectric dams, all of it within spitting distance of the mighty Columbia River. 

Read More


 

Product News

  • Prev
Introducing the new in-sourced, upgraded, and expanded vapor tight LED High Bay -- the ...
Klein Tools introduces the new Magnetic Wire Puller, to help professionals quickly and easily fish ...
Siemens new 3VA molded case circuit breakers offer safe, efficient and variable application options ...
Hubbell’s illuminated plugs and connectors are the latest addition to the already broad line of ...
The ABV is a specification high bay that provides high performance and reliability. Available with ...
The Vive PowPak phase select dimming module is a radio frequency (RF) control that operates phase ...
6 functions in one pair of pliers. Multifunctional pliers for the electrical installation; to grip ...
With the ABB StarTeck® selector web app you can match cables with Teck fittings quickly and easily. ...
WPS Gen 4 wall pack series is a classic and familiar design integrated with modern LED technology ...
These new controllers offer indoor or outdoor ON/OFF, photocell, dimming, scene and color tuning ...

 

Lumenquad New VersionsLumenpulse has announced the release of two additional smaller sizes of the Lumenquad, a rectilinear projector for both outdoor and indoor environments. Developed for architectural applications such as lighting landscapes, highlighting details, pathways and monuments, the Lumenquad Small and Medium are compact, low-wattage, high-performance projectors, complementing the two existing products in the family.

The Lumenquad Small and Medium are the latest additions to a family of sleek, elegant, high-performance projectors that has already been validated with honours, including recognition in the PIA Awards in 2019, together with a Lux Awards for Exterior Luminaire of the Year in 2019. 

Read More


 

 

Wiha Lineman's Pliers and CrimpersWiha Insulated SoftFinish® Cushion Grip Pliers and Cutters are the standard for premium quality featuring ergonomic cushion grip handles for comfort and control, dual durometer construction for long-lasting durability, and handles directly molded to the tool steel for a permanent bond.

The grips feature a slip guard handle design for added protection at the front-end and raised rear-finger steps for easy opening at the back-end. Wiha Insulated SoftFinish® Cushion Grip Pliers and Cutters consist of premium quality tool steel for strength and durability and induction hardened cutting edges and jaws for superior sharpness and longevity. 

Read More


 

 

eLumigen Poultry Lamps - 2000K, 3000K & 5000KIdeal for rough service applications, the A19 & PAR Series are engineered for high efficiency, vibration resistance, shatter-resistance, elevated heat environments, and wet locations. These dimmable LED Lamps help reduce energy costs, labor costs, and the headaches of frequent lamp changes in tough applications.

eLumigen employs a unique 21-point validation process that goes above and beyond industry standards. Our lamps have been tested to survive levels of vibration exceeding 20G forces. Our unique temperature foldback design improves both safety and thermal management of our lamps. 

Read More


 

Peers & Profiles

  • Prev
Bryan Smith started his now 20-year career at the ground floor, so to speak, as a draftsperson and ...
From small construction to sophisticated industrial projects, House of Electrical Supplies has been ...
Kyle Manfredi is the owner of ARK Electrical alongside his wife, Shannon. Operating out of ...
Like most major events over the last year, the COVID-19 pandemic put serious restrictions on the ...
This past December Jennifer Green was honoured with Canada’s Most Powerful Women Top 100 Award for ...
“It was quite surprising,” said Stephanie Smith of being named EHRC’s Leader of the Year. ...
As an advanced networked lighting controls company serving the industrial and large commercial ...
Trilliant, an international provider of utility solutions for advanced metering and smart grid ...
For more than a century, ABB has been investing in Canadian technologies and products to support ...
Mackenzie Gillan, a bright young lady from Baysville, Ontario, tells us about how she learned ...


House of Electrical SuppliesFrom small construction to sophisticated industrial projects, House of Electrical Supplies has been servicing clients in the industrial, OEM, entertainment, and construction markets across the Greater Toronto Area for just over 40 years. The company has earned a reputation for providing a high-quality customer experience.

As per President Austin Brennan, their experienced and knowledgeable team can be depended upon in any situation to deliver quick and efficient service. On top of their product solutions — ranging from electrical, automation, safety, lighting and portable power distribution — 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2021 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil