Bill BurrIn this article: Section 52 — Diagnostic imaging installations. The CE code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook**, but will hopefully provide some help in navigating the code.

Rule 52-000 Scope states that Section 52 is a supplementary or amendatory section of the code and applies to the installation of X-ray and other diagnostic imaging equipment operating at any frequency, but does not provide any specifications for safeguards against radiation. Information on radiation safeguards is contained in the series of Health Canada Safety Codes for radiation protection. The CSA CEC Handbook provides additional explanations and tables.

Rule 52-002 provides some special terminology for this section, and defines momentary and long-term ratings of 20 seconds and 5 minutes respectively for operation of applied x-ray and computerized tomography equipment.

Rule 52-004 provides guidelines for guarding of high-voltage parts, and requires that high-voltage parts be contained within bonded to ground metal enclosures, or within separate rooms or enclosures where a circuit control switch controlling the diagnostic imaging equipment is interlocked, to be open when the door is open and unlocked, and be insulated from the enclosure. In addition, high-voltage circuit conductors must be of the shockproof type. If a milliammeter is provided, it must be either connected in the bonded-to-ground circuit conductor, or guarded, if connected in the high-voltage conductor.

Rule 52-006 permits mobile diagnostic equipment, and permanently connected diagnostic equipment on a 30 amp or less branch circuit, to be supplied with a plug and hard-usage cable or cord.

Rule 52-008 specifies that a disconnect must be placed in the supply circuit in a location accessible from the radiation control of the diagnostic equipment. The rating of the disconnect for X-ray or computerized tomography equipment is based on 100% of the power input required for the long-time rating of the equipment, or 50% of the power input required for the momentary rating of the equipment, whichever is greater. For equipment on a 120volt, 30amp circuit, the required disconnect may be a receptacle and plug of the appropriate size.

Rule 52-010 exempts transformers and capacitors, forming part of diagnostic imaging equipment, from the requirements of Section 26. This equipment must comply with the CEC Part II product standard for the equipment. Capacitors must be provided with a means for automatically discharging and grounding the plates when the supply is disconnected. This is not required if the current-carrying parts of the capacitors and conductors are located 2.5 meters or more above the floor and accessible to only authorized persons, or, if located within 2.5 meters of the floor, within

• metal enclosures that are bonded to ground, or
• enclosures of insulating material

Rule 52-012 provides for protection where step-up transformers are used for diagnostic equipment. The low-voltage circuit of the step-up transformer is required to have an overcurrent device with no exposed live parts, installed as part of or adjacent to the equipment that protects the high-voltage radiographic circuit from all fault conditions. Where the above overcurrent device is too large to protect other fluoroscopic or therapeutic circuits on the equipment, additional overcurrent protection needs to be installed to protect these circuits. In the case of portable equipment, the above requirements also apply. However, an exemption can be applied if all high-voltage parts are enclosed in a single metal enclosure, bonded to ground. Where more than one apparatus is supplied by a common high-voltage source, other switches must be installed to independently disconnect each apparatus from the high-voltage source.
Rule 52-014 reiterates that all non-current-carrying parts of apparatus, including ancillary equipment, must be bonded to ground in accordance with the requirements of Section 10.

Rule 52-016 provides the requirements for determining ampacity of supply conductors and rating of overcurrent protection for diagnostic imaging equipment. For a single piece of equipment, use the larger of

• the long-time current rating of the equipment, or
• 50% of the momentary current-rating required on a radiographic setting

Note that this information is contained on the equipment faceplate.

Where more than one piece of diagnostic equipment is supplied, the rating of the supply conductors and overcurrent device is based on

• the sum of the long time current ratings of all the equipment supplied by the circuit, or
• Tthe sum of 50% of the maximum momentary current rating for the two largest units supplied, plus 20% of the maximum momentary current rating of the other units, when the equipment is on a radiographic setting

In the next installment, we will be discussing Section 54 — Community antenna distribution and radio and television installations.

* The source for this series of articles is the Canadian Electrical Code, Part I, published by CSA
** Note the CEC Handbook is also published by CSA.

William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

AD Spotlight                                                                                                            

Changing Scene

  • Prev
EFC’s exciting new product section on Electric Vehicle Systems conducted its first face-to-face ...
Canadian battery material specialist Hydro-Québec partners with Mercedes-Benz AG as part ...
Employer response to emerging technologies’ impact on the electricity sector workforce is critical ...
The National Electrical Manufacturers Association (NEMA) has published two new standards on ...
This fall, Canada's elite electricians and apprentices will be heading to Nashville, Tennessee for ...
The Electrical industry is “Powering a Changing World” in areas such as digitization, ...
Prior to joining ABB in 2017 as Executive Vice President of the Electrification business, Deschenes ...
The Canadian Apprenticeship Forum-Forum Canadien sur l’Apprentissage (CAF-FCA) has announced ...
The Support Equity and Under-Represented Groups project will address the under-representation of ...

SIemens Light+BuildingAt this year’s Light+Building trade fair, Siemens will showcase its vision for transforming today’s passive buildings into learning and adaptive environments that intelligently interact with people. The company’s focus at this year’s show is “Building the future today”, outlining the innovations that will make this possible. These include cloud-based technologies, digital planning, occupant-centric building automation and services. New solutions for smart electrical infrastructure that seamlessly connects to the Internet of Things (IoT) are also at the core of this transformation.

Read More

 

 

 

Latest Articles

  • Prev
I once took a class where the professor would explain concepts in two ways. First, he would dive ...
A broadening of the role of luminaires and a continued focus on people and energy efficiency are ...
There’s been a lot of confusion and misinformation disseminated regarding LED emergency lighting ...
We are in an Age of Disruption. Extant and emerging technologies are driving significant evolution ...
Often, code users encounter situations where they find themselves at odds with the rules contained ...
The new electrical code includes several changes to support electrical workers in the safe ...
Anyone working in the electricity sector in Canada knows the reality of how few women we have in ...
 Anyone working in the electrical industry knows the importance of labelling for both safety ...

Michelle BraniganBy Michelle Branigan

We are in an Age of Disruption. Extant and emerging technologies are driving significant evolution in the way work is done across all sectors of Canada’s economy and no industry, including electricity, will be immune.

Think of the technologies and businesses that have changed the way we live, work and connect with each other. Uber. Airbnb. Spotify. Facebook. Twitter. Duolingo. The list is long and what’s fascinating is that these are companies that did not exist 20 years ago. Yet these are common words in our lexicon today.

Read More

 

 


Greenlee Voltage DetectorsProfessionals searching for a reliable voltage detection solution have two new Greenlee options — the newly redesigned GT13 and TR13 non-contact voltage detectors. The new testers identify the presence of voltage from 50 volts to 1,000 volts AC. The redesigned GT13 and TR13 are now equipped with a more ergonomic grip and button location, along with a bright LED flashlight for use in dark work areas.


 

Read More

 

Product News

  • Prev
The controlHUBB Mobile App provides Bluetooth® wireless setup and configuration of NX Room Control ...
The LED filament lamps distinguish themselves by their sparkling white light, blending perfectly ...
Stanpro offers a wide range of Linear Fluorescent lamps for all lighting applications and needs. ...
This modern design series is a family of highly efficient and powerful LED flood lights and area ...
Our new 60W and 100W Temporary LED High Bays are the ideal substitute for traditional 250W and 400W ...
These high quality luminaires are equipped with a frosted lens that diffuses the light comfortably. ...
Arlington’s #300 non-metallic cable strap offers the easy way to attach flat NM cable to concrete ...
EiKO's Emergency Batery Kit is an LED emergency driver that allows the same LED fixture to be used ...
The LED Gimbal High Output downlight combines a sleek design with a small aperture without any ...
LPDL (Low Profile Downlight) gives you all the flexibility you need during installation, especially ...

 

Lumenwerx AcoustixLumenwerx is pleased to announce the launch of a new suite of acoustic luminaires to reduce ambient noise – ACOUSTIX family.

Developed in conjunction with acoustics experts, the new ACOUSTIX family of luminaires combines exceptional optics and precision sound absorbing technology to create a new paradigm in acoustic lighting. The lineup’s flagship fixture, the Audia, can increase sound absorption up to 30% more than competing products.

 

 

Read More

 

 


 

Leviton Nick FosterBy Blake Marchand

Nick Foster is Territory Manager, New Brunswick & P.E.I for Leviton. Foster was recently appointed as the Atlantic Regional Chair for Electro-Federation Canada’s (EFC) Young Professional Network (YPN).

Nick joins newly appointed National Chair, Sean Bernard of Ideal Industries, Ontario Region Chair, Joanna Kwant of Gerrie Electric, and Quebec Region Chair, Jean-Francois Gravel also with Leviton.

 

 

Read More

 

 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2020 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil