Rule 26-706 specifies that all receptacles of CSA configuration 5-15R and 5-20R installed in:

  • childcare facilities.
  • guest rooms and suites of hotels and motels.
  • preschools and elementary education facilities; or
  • dwelling units the following locations

…must have a particular feature, what is this feature?

They must be tamper-resistant receptacles and be so marked except for receptacles dedicated for stationary appliances where the receptacle is inaccessible or located above 2 m from the floor or finished grade.

Read more on Section 26

Source: CSA C22.1:24, Canadian Electrical Code, Part 1 – Safety Standard for Electrical Installations. © 2021 Canadian Standards Association. Please visit Store – CSA Group or call 1-800-463-6727. With the permission of CSA Group, the material is reproduced from CSA Group standard CSA C22.1:21, Canadian Electrical Code, Part 1 – Safety Standard for Electrical Installations. This material is not the complete and official position of CSA Group on the referenced subject, which is represented solely by the Standard in its entirety. While use of the material has been authorized, CSA Group is not responsible for the manner in which the data are presented, nor for any representations and interpretations. No further reproduction is permitted. For more information or to purchase standard(s) from CSA Group, please visit Store – CSA Group or call 1-800-463-6727.

Related Articles


Latest Articles


Changing Scene

  • Supporting Enoch Cree Nation’s Long-Term Housing Strategy and Community Growth

    Supporting Enoch Cree Nation’s Long-Term Housing Strategy and Community Growth

    November 9, 2026 The Canada Infrastructure Bank (CIB) has reached financial close on a $30 million loan towards enabling infrastructure for critical housing development on ECN reserve lands, near Edmonton, Alberta. The project will address exponential housing pressures within the community, allowing ECN members to return to community while supporting long-term growth on reserve.  The… Read More…

  • BCCSA Invests $100,000 to Strengthen BC’s Future Construction Workforce

    BCCSA Invests $100,000 to Strengthen BC’s Future Construction Workforce

    November 5, 2026 The British Columbia Construction Association (BCCA) is pleased to recognize a generous $100,000 contribution from the BC Construction Safety Alliance (BCCSA) Research, Development, and Opportunity Fund (RDO Fund) in support of Honour the Work, a national initiative dedicated to introducing young people to the skilled trades and building awareness of career opportunities… Read More…

  • New Tool in New Brunswick Proposed to Encourage Development of Vacant Properties

    New Tool in New Brunswick Proposed to Encourage Development of Vacant Properties

    November 5, 2026 The government has introduced amendments to the Local Governance Act that, if passed, would give local governments the authority to develop and impose a vacant property levy. “Local governments have been asking for more tools to help put vacant properties to better use,” said Local Government Minister Aaron Kennedy, who is also… Read More…

  • TechnoVE EcoWatt Program

    TechnoVE EcoWatt Program

    November 5, 2026 TechnoVE believes that every charge can have a positive impact, for the environment and for your wallet. That’s why they have created the EcoWatt Program: an exclusive initiative that allows you to make the most of your energy consumption while contributing to the ecological transition. Requirements Terminal compatibility: To perform this update,… Read More…