How ABB’s Hi-Tech Valiant™ Current Limiting Fuse for Fire Mitigation Impacts Safety & Reliability, Protecting the Environment & Critical Infrastructure

March 13, 2025

By Blake Marchand

There has been increased awareness on the impact of forest fires in recent years, as wildfire seasons have intensified in North America. We recently saw devastating fires in California, and in Canada, statistics show that each year wildfire seasons are getting longer and more disastrous. 

The 2023 wildfire season in Canada was the worst on record and the most destructive by a large margin. According to Natural Resources Canada, the 2023 wildfire season had 6,000 fires across 15 million hectares of land. That is twice the size of the previous record year, 1989. For context, the average land coverage of a wildfire season in Canada is 2.5 million hectares. 2023 was also marked by the intensity of fires, there were 29 ‘mega-fires’ that each exceeded 100,000 hectares. As well as being widespread across the country, with fires from the West Coast to Atlantic provinces, with fires in B.C., Alberta, Saskatchewan, Manitoba, Ontario, and Quebec. The West Coast was the hardest hit.

“The word ‘unprecedented’ doesn’t do justice to the severity of the wildfires in Canada this year (2023),” noted forest ecology research scientist Yan Boulanger as part of Natural Resources Canada’s press release on 2023 wildfire season. “From a scientific perspective, the doubling of the previous burned area record is shocking.”

How ABB’s Hi-Tech Valiant™ Current Limiting Fuse for Fire Mitigation Impacts Safety & Reliability, Protecting the Environment & Critical Infrastructure
ABB’s Fire Mitigation Fuse on display at EDIST earlier this year.

Dominique Tardif, Product Line Manager with ABB, noted that Electricity Canada has identified the installation of non-expulsion fuses as best practices for utilities to wildfires.

The conversation around their fire-mitigation fuse is often driven by utility executives, Tardif noted, because of the impact on safety, as well as protecting grid infrastructure. The product was initially developed for a client in the U.S. and ABB is currently refining it for a Canadian utility and tailoring it for the broader Canadian market.

The initial design was for a 15 kV system, and they are now working on a version at for the Canadian market at 25-27 kV, “It sounds like a simple jump,” he said, “but that is quite a bit more energy traveling in the same size conductors.”

“The launch plan centers, of course on the customer that wanted it initially, and, we’re giving preference to, we’re making sure we’re supporting them very closely. Doing the fit, form and function with them, we’re on our third iteration of the said fuse design.”

Tardif said they are in the process of finalizing the product for a Canadian utility, “as you can imagine in any product development, we’re always refining, making it a little bit better, a little bit more efficient… And then of course, as the 2025 year goes on, we’ll be able to launch this across the country.”

The Hi-Tech Valiant full-range current-limiting fuse functions like the traditional kickout fuse, Tardif explained, “The traditional fuses, when they detect that there’s going to be a high voltage condition or a high energy condition – basically, the contents inside burn out and are ejected from the inside of the fuse into the environment. The high-tech fire mitigation fuse uses a technology that has encapsulated this ejecta.”

“When the overload happens, the tube is large enough to be able to contain the energy, contain the molten material.” he said, “none of the ejecta goes into the environment, everything stays within the fuse.”

When the cut out opens, the energy is let off the system, “preventing any potential for the ignition of forest fires or any ignition of any material that’s at the base of the pole,” so, you are providing additional protection for critical infrastructure.

The fuse includes soldered/welded electrical connections and features high fault interrupting capability up to 50 kA symmetrical. Current limiting fuses minimize the risk of eventful distribution equipment failure by limiting the peak current let through during a fault. Expulsion fuses and breakers can take several cycles to interrupt and don’t limit the energy let through during a fault.

Beyond the increased focus on wild-fire mitigation, the Hi-Tech Valiant Full-range Current-limiting Fuse has a general safety- focused application, as well – to help. When you look at protecting critical infrastructure, as well as residential areas.

Going underground has become a key strategy for creating resilient infrastructure, although, “We have to admit, not every downtown core or not every suburban core is underground yet – because as the grid resiliency has been improved, one of the solutions is to start burying the cables and starting to go into underground systems – there are some older neighborhoods where going underground is going to be prohibitive or just an extreme hassle. factor, right?”

Remote, heavily forested areas where fire mitigation is a key focus was the driver to develop the technology, but the application is broader from a safety, fire mitigation, and resiliency perspective.

In discussions with potential clients, Tardif said, “They’re starting to see that it’s not just fire mitigation to prevent forest fires, it’s fire mitigation.” And with the continued approach to safety in the energy sector, he added, “this is something that we feel can really bring some significant benefit to the utilities.”

  • Hi-Tech damage sensor included as standard — helps protect against undetected damage to the fuse that could compromise equipment protection
  • Unique, patent-pending engagement pin for easy vertical and rotational alignment during installation
  • Actuating pin remains external to the fuse after operation — eliminating the possibility of reclosure
  • Multi-seal design seal to prevent water intrusion
  • Provides robust electrical contact
  • Uses a mechanical spring for operation — contains no black powder or other explosive material

Related Articles


Latest Articles

  • Prysmian’s $3.8B Atkore Deal would add Quebec Fiberglass-Conduit Plant to Canadian Footprint

    Prysmian’s $3.8B Atkore Deal would add Quebec Fiberglass-Conduit Plant to Canadian Footprint

    August 4, 2026 Prysmian’s proposed US$3.8-billion acquisition of Atkore is primarily a move to deepen the Italian cable manufacturer’s U.S. electrical-products presence, but it also carries a meaningful Canadian angle for the electrical channel. If the transaction closes as expected, Prysmian would add Atkore’s FRE Composites manufacturing operation in Saint-André-d’Argenteuil, Que., near Montréal, to its… Read More…

  • Technical Safety BC Top 5 Safety Risks in 2025

    Technical Safety BC Top 5 Safety Risks in 2025

    July 31, 2026 Each year, Technical Safety BC measures the data they receive through incident and hazard reports to analyze and rank the top safety risks encountered across the province. These risks were identified by collecting, assessing, and analyzing incident investigation data. The key metrics they look at when ranking the top five safety risks… Read More…

  • World Youth Day Spotlight: Supporting Habitat for Humanity Canada’s Youth Skills Building Program

    World Youth Day Spotlight: Supporting Habitat for Humanity Canada’s Youth Skills Building Program

    July 31, 2026 By Electro Federation Canada This World Youth Day, we are proud to recognize the positive impact EFC members continue to make through their support of Habitat Canada’s Youth Skills Building Program. Investing in the Next Generation of Talent Canada is experiencing a significant labour shortage that is delaying homebuilding, driving up costs,… Read More…

  • Current Carrying Capacity: How to Determine the Right Conductor Cross-Section

    Current Carrying Capacity: How to Determine the Right Conductor Cross-Section

    July 31, 2026 Current carrying capacity means the maximum current that a cable can transmit over sustained periods without overheating. Exceeding the permitted current capacity can damage the cable’s insulation and, in the worst case, result in fire. What determines the current carrying capacity? Different parameters influence how much electricity a cable can safely transmit.… Read More…


Changing Scene

  • Nexans Canada Celebrates 60 Years of Electrifying Canada from Fergus, Ontario

    Nexans Canada Celebrates 60 Years of Electrifying Canada from Fergus, Ontario

    Canada’s largest wire and cable manufacturer marks six decades of continuous manufacturing in Centre Wellington… Read More…

  • Mac’s II Agencies Expands Industrial Portfolio with Five Hubbell Brands

    Mac’s II Agencies Expands Industrial Portfolio with Five Hubbell Brands

    August 5, 2026 Mac’s II Agencies is expanding its electrical portfolio across British Columbia and Yukon with five leading brands from Hubbell, enhancing our ability to support hazardous location and industrial project business with reliable, field proven solutions for demanding environments. From explosion proof distribution equipment and industrial lighting to the connectors, glands, and hardware that tie… Read More…

  • Prysmian’s $3.8B Atkore Deal would add Quebec Fiberglass-Conduit Plant to Canadian Footprint

    Prysmian’s $3.8B Atkore Deal would add Quebec Fiberglass-Conduit Plant to Canadian Footprint

    August 4, 2026 Prysmian’s proposed US$3.8-billion acquisition of Atkore is primarily a move to deepen the Italian cable manufacturer’s U.S. electrical-products presence, but it also carries a meaningful Canadian angle for the electrical channel. If the transaction closes as expected, Prysmian would add Atkore’s FRE Composites manufacturing operation in Saint-André-d’Argenteuil, Que., near Montréal, to its… Read More…

  • Apply for ECAO 2026 Scholarships

    Apply for ECAO 2026 Scholarships

    July 31, 2026 It is that time of year again when ECAO are offering scholarships to post-secondary graduates for children or wards of salaried employees of ECAO Member Companies. The scholarship was launched in 2004 and awards 5 successful recipients with a scholarship of $5,000 each. The scholarship will be awarded to outstanding students enrolling… Read More…