Section 38 — Elevators, dumbwaiters, material lifts, escalators, moving walks, lifts for persons with physical disabilities, and similar equipment.

The Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook, but will hopefully provide some help in navigating the Code. These notes are based on the 25th edition.

The Numbering of the rules in Section 38 is an exception to the numbering system outlined in the Preface of the Code. The numbering of the rules in this section corresponds with the rule numbers of associated rules in the ASME A17.1/CSA B44, Safety Code for Elevators and Escalators and the CSA-B355, Lifts for Persons with Physical Disabilities. The reason for this is that most of these rules will be used by elevator constructors.

Rule 38-001 Scope points out that this section is amendatory or supplementary to the general rules of the Code and applies to the installation of electrical equipment and wiring of elevators and similar equipment as per ASME A17.1/CSA B44, Safety Code for Elevators and Escalators; CSA B44.1/ASME A17.5, Elevator and Escalator Electrical Equipment; CSA B355, Lifts for Persons with Physical Disabilities; and CAN/CSA-B163, Private Residence Lifts for Persons with Physical Disabilities.

Rule 38-002 Special terminology contains definitions for specific equipment – Motor controller, Operating device, and Signal equipment. Note that control equipment may be located in a single or multiple enclosures.

Rule 38-003 Voltage limitations outlines that generally voltage is limited to 300 volts except it is limited to 750 volts for:

• branch circuits to door operator controllers,

• door motors,

• heating and air-conditioning equipment, located in the car,

• branch circuit and feeders to motor controllers,

• driving machine motors,

• machine brakes, and motor-generator sets.

Branch lighting circuits are limited in accordance with Section 30. Note that CSA B44.1/ASME A17.1 also has voltage limitations within equipment.

 Live parts enclosed requires that all live parts that can be contacted by users of the device must be enclosed to protect against accidental contact.

Rule 38-005 Working clearances - as an exception to the Requirements in Rule 2-308, the minimum headroom in working space around elevator associated electrical equipment is 2M. In addition, the working space of 1M in Rule 2-308 need not apply where only authorized persons have access and where other conditions as listed in sub-rules (2)(a) to (d) exist.

Rule 38-011 Insulation and types of conductors – conductors in hoistways, cars, platforms, wellways, machine rooms, and between the car or counterweight and the raceway must be selected in accordance with Tables 11 or 19 and the specific conditions of use, and the requirements of Rule 2-130. Note that the insulation voltage rating of all conductors must be equal to the maximum nominal circuit voltage rating of any conductor within the same enclosure, raceway, or cable.

Rule 38-012 Minimum size of conductors – the minimum size for conductors in travelling cables is:

a) No.14 AWG copper or equivalent ampacity for parallel conductors for lighting circuits, and

b) No.20 AWG copper for operating, control, signal, and extra-low-voltage lighting circuits.

The minimum size of conductor for all other operating, control, signal, and communications circuits must be No. 26 AWG copper.

Rule 38-013 Ampacity of feeder and branch-circuit conductors - the ampacity for conductors supplying:

• the driving motor of the motor-generator set supplying power to the driving machine motor of a unit with generator field control, is based on the nameplate current rating of the driving motor.

• a single motor is based on Rule 28-106 and Table 27.

• a motor controller is based on the motor controller nameplate current rating plus all other connected loads.

• a single power transformer is based on the nameplate current rating of the power transformer plus all other connected loads.

• more than one motor, motor controller, or power transformer is based on the sum of the nameplate current ratings of the equipment plus all other connected loads. Ampere ratings of the motors are based on Rule 28-108 and Table 62.

Rule 38-014 Feeder demand factor – select from Table 62.

Rule 38-015 Motor controller rating – select according to Rule 28-500(1) except when the controller inherently limits the available power to the motor and is marked “power limited”.

Rule 38-021 Wiring methods outlines the various wiring methods for specific equipment and locations for:

• elevators: hoistways, cars, within machine rooms, control rooms and machinery spaces, control spaces, and counterweights.

• escalators: insulated conductors and cables used in Class 1 extra-low voltage and Class 2 low-energy circuits, extra-low-voltage control cable, communication cable, fire alarm and signal cable, multiconductor jacketed thermoplastic-insulated cable, hard-usage cable, extra-hard-usage cables, flexible cords and cables that are components of approved equipment and used in extra-low-voltage circuits.

• lifts for persons with physical disabilities: Insulated conductors and cables used in Class 1 extra-low voltage and Class 2 low-energy circuits, flexible cords and cables that are components of approved equipment and used in extra-low-voltage circuits (30 V or less).

Rules 38-022, to 38-025 outline the requirements for provision of single, sole, or separate branch circuits, for specific lighting, receptacles, other utilization equipment used in conjunction with Section 38 devices, or locations. In addition these rules specify locations for required lighting control switches and prohibit required lighting to be supplied from the load side of a GFCI.

Rules 38-032 and 38-033 reference Rule 12-910 and Table 8 for metal, non-metallic wireways and number of conductors in raceways.

Rule 38-034 Supports outlines that cables or raceways must be securely fastened to guide rails, moving walk trusses or hoistways, wellways, or runways construction.

Rule 38-035 Auxiliary gutters references Rules 12-1900, 12-1902, and 12-1904.

Rule 38-036 Grouping of insulated conductors lists cables and insulated conductors that are permitted to be run in the same raceway or travelling cable if all are insulated for the maximum voltage.

Rule 38-037 Wiring in hoistways, machine rooms, control rooms, and machinery spaces and control spaces specifies that only insulated conductors used in connection with the operation, protection, communication, control or lighting and ventilation of equipment covered by Section 38 is permitted to be installed in hoistways, runways, machine rooms, control rooms, machinery spaces, control spaces or escalator wellways.

Rule 38-041 Suspension of travelling cables lists the locations and methods of suspending travelling cables.

Rule 38-042 Hazardous locations references Section 18.

Rule 38-043 Location of and protection for cables requires minimizing any possible damage to conductors and, where necessary, protecting with guards.

Rule 38-044 Installation of travelling cables provides that travelling cables suitably supported and protected from damage need not be installed in conduit or raceway.

Rule 38-051 Disconnecting means sets out the need to provide:

• characteristics, visibility, indication, identification, accessibility, and location of disconnecting means for all ungrounded conductors of:

• drive motors, ventilation, heating, air-conditioning, lighting, and control circuits for each device covered by this Section.

• It requires that there be only one disconnect for multiple driving machines of single devices, and

• that a sign identifying the location of supply side overcurrent devices be provided.

The rule also prohibits automatic closing of disconnection means on power failure restoration and requires manual closing only.

38-052 Power from more than one source requires that in single and multi-car installations, where equipment is supplied from more than one power source, a single disconnect is provided within sight of all the equipment served. Where parts of controllers or interconnection of controllers are energized from a different source a clear, legible warning sign is required.

Rules 38-053 and 38-054 requires that:

• single, enclosed, externally operable, fused motor circuit switches or circuit breakers,

• capable of being locked in the open position,

• for disconnecting all ungrounded car light, receptacle, ventilation, heating, and air-conditioning supply conductors,

be located in the machine or control room for that car.

The disconnecting means needs to be numbered to correspond to the car light source it controls and be provided with a sign identifying the location of the supply overcurrent device.

Rule 38-055 Utilization equipment disconnecting means requires that:

• a single, enclosed, externally operable, fused motor circuit switch or circuit breaker,

• capable of being locked in the open position,

• for disconnecting each branch circuit for other utilization equipment supply conductors,

• be located in the machine or control room.

The disconnecting means needs to be numbered to correspond to identifying number of the equipment it controls and be provided with a sign identifying the location of the supply overcurrent device.

Rule 38-061 Overcurrent protection:

• References Section 14 and Section 16, for provision of overcurrent and protection for operating, control, signal, Class 2 extra-low voltage, and low-energy circuits.

• The overload protection for each ac drive motor of a Section 38 device, or of a motor-generator set supplying current to the machine-drive motor, is selected in accordance with Rule 28-302.

• Overload devices shall be provided for each dc machine-drive motor providing power to two drive motors, and where the overcurrent protection of Section 14 is inadequate, or subject to reduced voltage during levelling.

Rule 38-062 Selective coordination requires overcurrent protection to be coordinated with upstream overcurrent devices.

Rule 38-071 Guarding equipment requires that driving machines, motor-generator sets, motor controllers, and disconnecting means shall be installed in a room or space that is secured against unauthorized access except where motor controllers are:

• in enclosures with doors or removable panels capable of being locked in the closed position, and the disconnecting means is integral to or adjacent to the motor controller,

• in enclosures that are in the balustrade on the side away from the moving steps or treadway,

• provided as an integral part of the motor controller, operable without opening the enclosure,

• in elevators with driving machines located on the car, counterweight, or in the hoistway and driving machines for dumbwaiters, material lifts, and lifts for persons with physical disabilities.

Rules 38-081 to 38-084 specify that all metal parts of Section 38 devices must be bonded to ground in accordance with Section 10.

Rule 38-085 Ground fault circuit interrupter protection for personnel requires that:

• except for a single receptacle supplying a permanently installed sump pump, each 125V, single-phase receptacle installed in pits, hoistways, elevator and enclosed vertical lift car tops, escalator and moving walk wellways shall be a Class A GFCI type.

• all 125V, single-phase receptacles installed in machine rooms and spaces shall have Class A GFCI protection.

Rule 38-091 Emergency power provides guidelines for operation of elevators from an emergency power supply in the event of normal power failure:

• Where the elevator system regenerates power back into a power source that may be unable to absorb it, other building loads, such as power and lighting, that are automatically connected to the emergency power may be utilized to absorb the regenerative power.

• A disconnecting means in accordance with Rule 38-051 must disconnect both the emergency power source and the normal power source.

• Where an additional power source is connected to the load side of the disconnecting means, which allows automatic movement of the car or movement of the carriage controlled by users, the disconnecting means shall be provided with an auxiliary contact that:

a) mechanically opens positively,

b) is not solely dependent on springs, and

c) must cause the additional power source to be disconnected from its load when the disconnecting means is in the open position.

In the next installment, we will be discussing Section 40 — Electric cranes and hoists.

Source: CSA C22.1:21, Canadian Electrical Code, Part 1 - Safety Standard for Electrical Installations. © 2021 Canadian Standards Association. Please visit store.csagroup.org. With the permission of CSA Group, material is reproduced from CSA Group standard CSA C22.1:21, Canadian Electrical Code, Part 1 - Safety Standard for Electrical Installations. This material is not the complete and official position of CSA Group on the referenced subject, which is represented solely by the Standard in its entirety. While use of the material has been authorized, CSA Group is not responsible for the manner in which the data are presented, nor for any representations and interpretations. No further reproduction is permitted. For more information or to purchase standard(s) from CSA Group, please visit store.csagroup.org or call 1-800-463-6727.

William (Bill) Burr is an associate member of the Canadian Electrical Code, Part 1, Technical Committee and formerly Chair of the Canadian Advisory Council on Electrical Safety (CACES), Chief Electrical and Elevator Inspector for the Province of BC & the Northwest Territories, Director of Electrical and Gas Standards Development and Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

Changing Scene

  • Prev
The Electrical Contractors Association of BC (ECABC) has announced the impending departure of ...
The Minister of Employment, Workforce Development and Disability Inclusion, Carla Qualtrough was at ...
The launch of the Apprenticeship Service stands to help overcome financial barriers employers face ...
The National Electrical Trade Council (NETCO) is pleased to announce that they will be rolling out ...
43 years ago, Steve Silverstein bought a table saw and a delivery van and began a revolution in the ...
E.B. Horsman & Son (EBH) has announced their Victoria location will be officially moving to a ...
 The Maritime’s largest Mechanical and Electrical event took place last Wednesday and ...
IDEAL INDUSTRIES, INC. is calling all professional and student-apprentice electricians to come out ...
Vivi White has been appointed to the Board of Directors of the Electrical Safety Authority ...
The Sonepar Ontario Region is proud to announce the relocation of their SESCO Central Distribution ...

Become a Wiser Approved Installer

Wiser Approved Installer

Get access to exclusive benefits, product discounts and resources that will help you drive more business, and lower energy bills for your clients.

 

 

 

Read More


 



Vivi WhiteVivi White has been appointed to the Board of Directors of the Electrical Safety Authority (ESA) by the Honourable Ross Romano, Minister of Government and Consumer Services.

“As Chair, I am pleased that the Ontario Government recently appointed Vivi White to the Board,” said Annette Bergeron. “The Electrical Safety Authority’s efforts over the years have greatly improved the safety of the people of Ontario. It’s an important mandate and requires a strong, talented and diverse board as we transform into a modern regulator.”

 

Read more


 

Omnicable joins ETIMETIM North America announced that OmniCable has joined the product classification standards organization. Headquartered in West Chester, PA, OmniCable has 24 locations throughout North America, and also owns Houston Wire & Cable (HWC). The company partners with many electrical manufacturers and only sells to distributors.

According to John Dean, Director of Marketing & E-Commerce, OmniCable/HWC, “The wire and cable industry is often called commodities, but there are very distinct features and attributes for the different products our manufacturers produce. 

Read More

 


 

Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion

 


 

Grimard is More Competitive and Produces Estimates 3X Faster with Procore

ProcoreWhen the pandemic lockdowns started in March of 2020, Grimard (an electrical contractor) had to decide whether to shut down its operations entirely or implement a new platform with people who were now freely available for work. Once they implemented Procore, they found a way to efficiently communicate with stakeholders and offer full transparency in terms of project costs and planning. It also allowed Grimard to utilize historical data to make project estimates more accurate. Grimard was able to streamline its bidding process, which made it more attractive to potential clients and helped the business grow.

Read More


 



 

FlukeElectrical distribution problems are not always immediately identified as issues with power quality. An example of this is a thermal-magnetic circuit breaker. When it trips, the indication is generally a short circuit, ground fault, or overload. At times this can be put down to an old breaker that needs replacing.

However, it’s important to investigate the types of loads on the system and monitor harmonics for a potential disturbance. This article explores common issues with power quality and how to troubleshoot those issues.

 

 

Read More


 

EIN Romex 12 2 Recall 400This recall involves a yellow electrical wire, 12/2 NMD90 75M Romex SIMpull cable, sold by the spool. Products were also sold at Home Depot designated as article 108196.  Only cables with a time stamp between 12:41 and 18:02 are affected by this recall. 

The recalled product contains a neutral wire that is a smaller 14-gauge wire, contrary to the stamp on the wire identifying both the neutral and “hot” wires as 12-gauge (i.e., "12/2"). 

The recalled product contains a 14-gauge neutral wire instead of 12-gauge (as labelled), thus it may not perform as expected in 12-gauge applications, resulting in a risk of those applications having impaired performance and/or compliance with safety codes or standards.

Go HERE for more information


 

SimplySnap: It Just Works.

SynapseSmart technology is only smart if it works, and SimplySnap? It just works.
Scalable, field-proven, DLC NLC 5.0 qualified, and easy-to-install wireless network
lighting controls are in-stock. Explore energy code compliant SimplySnap
technology here.

Read More

 


 

Product News

  • Prev
Ericson announces upgraded versions of their extremely capable line of Industrial String Lights and ...
Intermatic Incorporated announced its new P40000 Series Load Centers, a set of next-generation ...
Klein Tools introduces new Stand-up Zipper Bags, in a 2-Pack with 7-Inch and 14-Inch sizes, ...
Cree LED, anSGHcompany, announced the launch ofXLamp® Element G LEDs, delivering a new ...
The Occupational Safety and Health Administration (OSHA) estimates 350 employees are killed ...
IDEC Corporation has released a complete product line of S3TL series ferrules, wire strippers, ...
Corning CCH pigtailed cassettes are factory assembled, quality tested, and available in LC and ...
QuickLink delivers the fastest downlighting installation HALO has to offer. Installers can power up ...
Kidde HomeSafe™ is a comprehensive suite of smart home safety devices to help protect against ...
Combination Couplings used to join 3/4" EMT conduit via set screw to 14/2 through 10/3 Steel and ...


Greenlee Mobile Bending Table for 881 Series Hydraulic BendersGreenlee is bringing secure and easy-to-transport conduit bending capabilities to jobsites with the introduction of its Mobile Bending Table for 881 Series Hydraulic Benders. The new product combines the latest in anti-theft protection with enhanced mobility, easy set-up and quick teardown.

“Electricians are constantly trying to do work more efficiently. Anytime we can shave time off a job, it’s a win – and this product delivers that with easier set-up and portability. At the same time, we know that protecting equipment from theft is an issue for a lot of tradespeople. The new Greenlee Mobile Bending Table for the 881 Series Hydraulic Benders is our latest solution to help professionals safeguard their investments and increase productivity,” 

Read More


 

 

Klein Tools Upgraded Testing KitKlein Tools introduces the Premium Electrical Test Kit.

Premium Electrical Test Kit (Cat. No. 69355)

  • Refreshed kit that features three new product releases geared towards a variety of electrical testing applications.
  • Kit includes instructions and all required batteries.

Manual-Ranging Digital Multimeter with Right-Angle Test Leads (Cat. No. MM320 – Exclusive to Cat. No. 69355 and Cat. No. MM320KIT)

  • Measures up to 600V AC/DC voltages, 10A DC current and 2-ohm resistance
  • Also tests batteries, diodes and continuity.

Read More


 

 

Brady M211Design, preview and print – all from your phone. Simple and intuitive, the M211 Label Printer is built for the job site, running all day on a full charge while resisting drops, shocks and crushes.

  • Simple. Easy. Intuitive.  Seamlessly design, preview and print labels from the industry leading Express Labels App on your familiar smartphone and swiftly connect to your printer.
  • Label it once.  Now with both pre-sized and continuous labels in 90+ cartridges, filled to the brim with reliable, tested and dedicated label materials that stay attached and remain legible on every surface and in any environment.

 

Read More


 

Peers & Profiles

  • Prev
Watt’s the Word is a recently launched Electrical Industry Podcast hosted by Zack Hartle and ...
Allana Kellett-Jamieson loves working in the electrical sector and is proud of the great focus ...
As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the ...
Karen Pullen knows what it’s like to be the only woman on a construction site, and as a proud ...
As of February 2021, Martin Stephenson is the new President and CEO of Signify Canada.   ...
This past July, Kerith Richards, who has worked for Service Wire Company for the last seven years, ...
EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, “After ...
Headquartered in Concord, Ontario, Mercury Lighting services national retail, ...
Among the recipients of the 2021 Clean50 Awards announced last month is Carolina Gallo, Vice ...
Sarah Silverstein is a principal with Liteline along side her two brothers Mark and Daniel. ...


Brent NeillyBy Blake Marchand

Brent Neilly is the Group Marketing Manager with Milwaukee, he has a background in business communications with a B.A. from Brock University, as well as experience working in the construction industry.

“When I joined TTI (Milwaukee’s parent company) it was kind of a perfect match, I had some marketing knowledge from my business degree and some industry experience from working in the trades.” Neilly gained his experience covering an area from Orillia to Timmins, Ontario when he first joined the company as a Field Sales Rep, as well as on their Job Site Core Trade Specialists in the GTA where he found his niche working with utility clients. 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2022 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil