Worldwide regulations require fire protection for emergency feeder circuits in commercial buildings, public spaces, hospitals, industrial plants and refineries. PYROTENAX System 1850 mineral insulated fire-rated cables are UL listed and can withstand temperatures up to 1850 °F / 1010 °C for two hours, ensuring critical equipment and processes continue to operate in the event of a fire.

nVent PYROTENAX System 2000 and 2200 2-hour fire-rated cables can withstand temperatures up to 2200 °F / 1200 °C for two hours, facilitating the controlled shutdown of critical processes and systems in the event of an industrial fire such as a hydrocarbon flash fire.

Historically, fire safety of critical circuits was achieved by running conventional cables behind a heat barrier such as a gypsum board or hollow concrete block; or by embedding the conductors in concrete.

nVent PYROTENAX System 1850 Bare Fire Rated Cable is a range of mineral insulated (MI) 2-hour fire-rated wiring cable for critical and essential circuit protection. It consists of solid copper conductors in a continuous copper sheath (System 1850) and is allowed to be used under virtually any application conditions by both the NEC and CEC. Cable terminations are typically field installed. Factory terminated wiring units are available in a range of sizes and lengths.

System 1850 Bare Fire Rated Cable
System 1850Z Jacketed Fire Rated Cable
Applications
  • Fire alarms and emergency lighting 
  • Fire pumps
  • Emergency elevators 
  • Smoke extraction and emergency ventilation fans in tunnels
  • Backup generators 
  • Industrial and petrochemical plants
  • And more 

nVent PYROTENAX mineral insulated cable combine dependability, versatility and performance with exceptional temperature and electrical performance. This inorganic and inherently fire-resistant construction means zero smoke, zero flames, and zero fuel contribution.

Features
  • Ultimate performance: fireproof, no smoke generation, zero halogens, high mechanical strength and corrosion resistance, waterproof and non-ageing
  • UL fire-resistive classified, does not require additional conduit or fireproofing
  • UL Classified/ ULC Listed: tested to the UL 2196/ULC-S139 fire test standards
  • Meets requirements of an Electrical Circuit Protective System, as referred to in Articles 695 and 700 of the National Electrical Code (NEC)
  • System 1850 appears in Electrical Circuit Integrity System (FHIT and FHIT7) of the UL/ULC Fire Resistance Directory

More Information

Related Articles


Latest Articles


Changing Scene

  • ECABC Announces 2026 Hall of Fame Inductees

    ECABC Announces 2026 Hall of Fame Inductees

    April 30, 2026 ECABC is proud to announce that Bill Strain and Rob Tate will be inducted into the ECABC Electrical Hall of Fame this June. Bill and Rob have devoted their careers to the electrical contracting industry in British Columbia. Induction into the Electrical Hall of Fame is the highest honour the Association can Read More…

  • Nexans Initiates Copper Mark Recertification for Montreal Site

    Nexans Initiates Copper Mark Recertification for Montreal Site

    April 27, 2026 Nexans Canada Inc. has initiated the Copper Mark recertification process for its site located at 460 Durocher Avenue in Montreal. As part of this process, an independent external assessment of the site is scheduled for April 22–24, 2026. Copper Mark is an independent assurance framework designed to assess the responsible practices of industrial sites against recognized Read More…

  • Fort Frances Memorial Sports Centre Adding Solar as Part of GICB Program

    Fort Frances Memorial Sports Centre Adding Solar as Part of GICB Program

    April 27, 2026 The Fort Frances Memorial Sports Centre will generate solar energy following an investment of $589,762 from the federal government through the Green and Inclusive Community Buildings (GICB) program. This funding will reduce greenhouse gas emissions and annual electricity costs for the facility. A rooftop solar generation system will convert solar energy into Read More…

  • IDEAL Electrical Announces $1M Donation and Partnership with Habitat for Humanity

    IDEAL Electrical Announces $1M Donation and Partnership with Habitat for Humanity

    April 27, 2026 In 2026, IDEAL Electrical will support four global Habitat for Humanity activations across Greater Toronto, Greater Chicago, the United Kingdom and Los Angeles/Southern California. These efforts will bring together IDEAL employees, electricians and apprentices, industry partners and electrical influencers to contribute more than 500 volunteer hours, $100K in materials and invaluable electrical skills Read More…