Improving Arc Flash Prevention and Safety

November 14, 2016

By Steve Sullivan

Working among the electrical components in an enclosure comes with inherent risks. The power in any one enclosure can range from 2kw up to 200kw depending on the power density. One of the most common and dangerous risks is an arc flash (or flashover).

When an explosive release of energy erupts from a phase-to-phase or phase-to-ground arc fault, the results range from devastating to deadly. This air to ground electrical explosion is a critical concern.

The destructive force of an arc flash

The dangers from an arc flash are all too well known. When metal expands and vaporizes at the fault, it causes extreme heating of the air, upwards of 10,000°C/18,032°F. The concussive pressure wave can knock personnel off their feet; the ultraviolet light flash can cause blindness; the sound blast, deafness; and the molten metal and heat can cause second and third degree burns. The specific death toll has been estimated to be up to 1-2 people every day worldwide.

An arc flash can result from unsafe work procedures, accidental contact, or more systemic problems such as corrosion of components and connections or insulation failure. Arc flash prevention should be incorporated into any application from the beginning of the design process.

Minimizing arc flash exposure

Design and retrofit approaches can limit exposure by using components installed outside the enclosure to permit qualified personnel in personal protective equipment (PPE) to service equipment inside without opening the enclosure door. Interface flaps and window kits permit data retrieval, equipment monitoring or routine maintenance to be performed from outside. Collapsible fold down shelves be raised for use with laptops and monitoring equipment. External data pockets can hold wiring diagrams, operation manuals and other documents.

Arc flash protection

Sometimes components must be accessed from inside the enclosure. For example, Rittal’s arc flash solution keeps high and low voltage equipment within the confines of their own respective enclosures. Low voltage enclosures house equipment that is used for programming, data acquisition and system adjustment.

High voltage components are isolated within their own disconnect enclosure, while line side power is segregated within the power isolation enclosure. A partition wall acts as a barrier to high voltage line side power. An interlocking door system ensures that the high voltage enclosure cannot be opened while the disconnect switch is in “ON” position.

For additional safety, all interlocked doors and master door must be closed in order to re-energize the enclosure. This removes potential for accidental contact with the inline power when the disconnect enclosure is put in a safe power-off position, and locked and tagged out.

Minimizing exposure to line side power can help protect personnel from accidents. A qualified person wearing PPE and following appropriate safe work practices can perform visual inspections and tasks, such as diagnosis, testing, troubleshooting and voltage measurement with the door open even when the main enclosure is energized.

Safety is always your priority, so download Rittal’s Arc Flash and How to Prevent it free whitepaper for the first step towards arc flash prevention: http://info.rittalenclosures.com/arch-flash-lp-0.

Steve Sullivan is a training manager with Rittal. This article was first published online as a blog: http://blog.rittalenclosures.com/blog/author/steve-sullivan-training-manager.

 

Related Articles


Latest Articles


Changing Scene

  • Mattr Completes Acquisition of AmerCable, Establishing US Wire and Cable Manufacturing Footprint

    Mattr Completes Acquisition of AmerCable, Establishing US Wire and Cable Manufacturing Footprint

    January 10, 2025 Mattr Corp. has announced that it has closed its previously announced acquisition of AmerCable Incorporated [see press release], which now forms part of Mattr’s Connection Technologies reporting segment. Under the terms of the transaction, Mattr has acquired all of the outstanding shares of AmerCable from Nexans USA Inc. for a purchase price… Read More…

  • Ontario Launches New Energy Efficiency Programs

    Ontario Launches New Energy Efficiency Programs

    January 10, 2025 The Ontario government is launching new energy efficiency programs, including the new Home Renovation Savings Program. The programs are part of a new $10.9 billion, 12-year investment in energy efficiency. The new Home Renovation Savings Program will launch on January 28, 2025, and offer rebates of up to 30 per cent for home energy… Read More…

  • The Government of Yukon Pauses the Affordable Heat Pump Program Due to High Demand

    The Government of Yukon Pauses the Affordable Heat Pump Program Due to High Demand

    January 9, 2025 The Affordable Heat Pump Program (AHPP) is fully subscribed through 2025, with 84 households receiving heat pumps through the program since the program launched on December 19, 2024. The rapid uptake of the program exceeded expectations, demonstrating Yukoners’ interest in switching to more efficient electric heating sources that result in lower utility… Read More…

  • Jesse Spring of Primary Engineering and Construction Named EHRC 2024 Leader of the Year

    Jesse Spring of Primary Engineering and Construction Named EHRC 2024 Leader of the Year

    January 6, 2025 Electricity Human Resources Canada (EHRC) is thrilled to announce Jesse Spring, CEO of Primary Engineering and Construction, as the recipient of the 2024 Leader of the Year Award. EHRC proudly recognizes Jesse for his leadership, which is built on excellence and powering growth. Jesse’s journey with Primary began in 2008 as an… Read More…