Part 1 – Basic Terminology

Arc flash, a type of electrical explosion, is one of the most complex workplace risks that exist. It is often described using technical terminology and acronyms. Below are the most important ones with simple explanation.

 

 

 

 

 BASIC INDUSTRY TERMINOLOGY

 Technical Terminology  Simple Explanation
 CSA Z462 and NFPA 70E  Workplace electrical safety standards for Canada (CSA) and the United States (NFPA). These best practice standards are technically harmonized and follow the same revision cycle (every 3 years).
 Arc flash PPE  Personal protective equipment (PPE) designed and tested to provide protection from the heat created by an arc flash hazard.
 Calories per cm2   Measurement of heat imposed on a surface area that is used to describe both the heat from an arc flash hazard (incident energy) and the protection provided by arc flash PPE (arc ratings). 
 Incident energy      Heat created by an arc flash measured as cal/cm2 (calories per square centimetre). Incident energy can be estimated using engineering calculations.
 Arc flash risk assessment  A requirement in CSA Z462 or NFPA 70E used as a process of identifying if an arc flash hazard exists; if yes, determine safety related work practices, arc flash boundary and the arc flash PPE required.
 Hazard/risk category (HRC)  Old method that is no longer relevant, which involved using tables from CSAZ462 or NFPA 70E to select arc flash and shock PPE for various work tasks and equipment.
 Arc flash PPE category  New method of using the tables from CSA Z462 or NFPA 70E to identify when arc flash PPE is required, and if required to select arc flash PPE based on different types of equipment.
 Detailed equipment label  Applied to electrical equipment to communicate important information related to the arc flash and shock hazards. Either the incident energy or the arc flash PPE category (but not both) is used to identify the potential arc flash hazard severity.
 Arc ratings  The protection provided by protective clothing and other types of PPE from the heat (incident energy) created by an arc flash. Determined by testing and reported on the product label.
 Types of arc ratings  Arc thermal performance value (ATPV): expressed using cal/cm2 to identify the incident energy level at which there is a 50% probability of sufficient heat transfer to cause the onset of a second-degree skin burn injury. 
   • Breakopen threshold energy (Ebt): expressed using cal/cm2 that identifies the incident energy level at which there is a 50% probability of the formation of holes or tears in the garment layer closest to the skin.

Jim Pollard is a member of several technical committees, including CSA Z462. He is the owner of Unlimited PPE in Stoney Creek, Ont., and can be reached at jim@unlimitedppe.com or (905) 573-0300.

Reprinted by permission of Canadian Occupational Safety © Thomson Reuters Canada Ltd., April/May 2015, Toronto, Ontario, 1-800-387-5164. Web: www.cos-mag.com.

Related Articles


Latest Articles


Changing Scene

  • Siemens to Establish Global AI Manufacturing Technologies R&D Center for Battery & EV Production in Canada

    Siemens to Establish Global AI Manufacturing Technologies R&D Center for Battery & EV Production in Canada

    May 26, 2025 Siemens will invest CAD $150 million over five years to establish a Global AI Manufacturing Technologies Research and Development (R&D) Center for Battery Production in Canada. The new R&D center, located initially at Siemens Canada’s head office in Oakville, as well as in Toronto and Kitchener-Waterloo, Ontario, will focus on developing cutting-edge AI manufacturing technologies with an initial emphasis… Read More…

  • Honda Postponing Ontario EV Supply Chain Investment by Two Years

    Honda Postponing Ontario EV Supply Chain Investment by Two Years

    May 26, 2025 Honda is postponing its plan to invest in a comprehensive EV supply chain in Ontario. The CBC reported that the investment is being push back by two years. “Due to the recent slowdown of the EV market, Honda Motor has announced an approximate two-year postponement of the comprehensive value chain investment project in Canada…. Read More…

  • Serge Leblanc Named Sonepar Canada Interim President

    Serge Leblanc Named Sonepar Canada Interim President

    May 26, 2025 George McClean, former President of Sonepar Canada, has decided to leave Sonepar for an opportunity outside of the electrical industry. Serge Leblanc, current President of Lumen Canada, has been appointed interim President of Sonepar Canada. Leblanc will manage both responsibilities until a successor is named.  Leblanc joined Lumen in 1997 and has… Read More…

  • Ontario Building and Construction Tradeswomen Head to Queens Park to Advocate for Safer, More Inclusive Job Sites

    Ontario Building and Construction Tradeswomen Head to Queens Park to Advocate for Safer, More Inclusive Job Sites

    May 26, 2025 On Monday, May 26, the Ontario Building and Construction Tradeswomen (OBCT), will host its first-ever Advocacy Day at Queen’s Park. Tradeswomen from across the province will gather to meet with Members of Provincial Parliament, including Minister of Labour David Piccini, to advocate for progress in the skilled trades for tradeswomen. OBCT’s top priorities include:… Read More…