Run 5 Essential Lighting Tests in 30 Seconds with Fluorescent Light Tester

Lighting Fluke


If you’re the building maintenance technician for a commercial, retail, or institutional facility with fluorescent lighting, you probably have hundreds or thousands of fluorescent tubes that have to be kept working. And even though those tubes last for tens of thousands of hours, they do fail, some prematurely. And some stop working because of other problems with the ballast they are installed in.

Photo: Red indicates “No Go.”

So if it’s your job to make sure that all those tubes are doing their job, you have quite a bit of ground to cover. In the past, that meant a lot of trial and error. If you found a light that was out, you’d have to climb the ladder, open up the cover, remove the bad tube and replace it. If the new tube didn’t light, you either tried again or had to call an electrician or bring out a voltage tester. That took more time and you hadn’t solved the problem yet.

Lighting Fluke 2

Photo2: Testing a ceiling light without a ladder

Addressing the needs of users in the field

After hearing this story more than a few times, Fluke decided to develop a tool that takes the trial and error — and a significant amount of time —out of maintaining fluorescent lighting. The result is the Fluke 1000FLT Fluorescent Light Tester, designed to meet the needs of building maintenance professionals. It is a fluorescent lamp tester, ballast tester, non-contact voltage tester, pin continuity tester, and ballast-type discriminator, all in one.

“We listened to customers and looked at what was out there and were able to incorporate all the functionality needed into a single tester that allows building maintenance technicians to troubleshoot all aspects of a fluorescent light system,” says Luis Silva, Product Marketing Manager at Fluke.

Five tests. No waiting

Some fluorescent lighting testers on the market may have one or two testing features. But Fluke wanted to develop a device that takes care of all the essential lighting tests, thus saving workers time, space in their tool bags, and trips up and down ladders. So, rather than having to carry two or three testing tools or call an electrician, they can just carry the 1000FLT to perform:

• Lamp test: Allows testing without removing the tube from the ballast. The tester sends a pulse of energy that lights up the tube if there is gas in it. The 1000FLT is compatible with T5, T8, and T12 fluorescent tubes.
• Ballast test: Easily determines whether the ballast is working.
• Non-contact voltage test: Quickly checks for the presence of voltage without touching the source.
• Pin continuity test: Tests whether filaments in the tube have continuity.
• Ballast-type discriminator: The 1000FLT is the first multi-function tester to include this feature to allow technicians to easily identify whether the ballast is electronic or magnetic without taking the fixture apart and without even climbing a ladder.

Just aim the tester at the ballast from the ground and it will immediately identify which type you have. This helps quickly identify old-style, power hungry magnetic ballasts, for maintenance or replacement.

The 1000FLT user interface was designed to be as simple as possible, and it is. All of these tests deliver instant results. The ballast, voltage, and pin continuity tests indicate results with either a “Go” or “No Go” indicator lights. The ballast-type discriminator lights up either the “magnetic” or “electronic” LED on the face of the tester, while the lamp test result is determined by the user if the tube lights up or not.

Save hours of testing time

You can run all five tests on the 1000FLT in about 30 seconds, so if you have hundreds of fluorescent lights to maintain, that can save hours of testing time every week. “One of our customers, which has one full-time and one half-time building maintenance pros dedicated to fluorescent light maintenance, estimated that together they saved about 40 to 60 minutes testing roughly 50 light fixtures per day with the 1000FLT,” says Silva.

Find out more: http://en-us.fluke.com/products/electrical-testers/Fluke-1000flt-fluorescent-light-tester.html.

Lighting Fluke 3
Testing a ballast with the Fluke 1000FLT Fluorescent Light Tester.

Related Articles


Latest Articles

  • Take the Lesson

    Take the Lesson

    September 2, 2024 By Keith Sones, seasoned utility industry executive “I really don’t want to do this.” “You have to Keith. You have no choice. You can’t leave him hanging” replied my wife. I stared at the phone like a child looks at liver on their plate. They know you have to eat it but also… Read More…

  • Quebec Drives the Growth in Residential Building Construction in June, 2024

    Quebec Drives the Growth in Residential Building Construction in June, 2024

    Investment in building construction grew 2.8% to $21.4 billion in June, after a slight increase of 0.8% in May. These increases partly reflect April’s record high of $13.4 billion in total building permits value, since investment levels for a given period are driven by permits issued in prior months. The June increase in investment in building construction was primarily… Read More…

  • Western Memorial Regional Hospital Sets New Infrastructure Precedent and Receives LEED Silver Certification 

    Western Memorial Regional Hospital Sets New Infrastructure Precedent and Receives LEED Silver Certification 

    August 16, 2024 The new Western Memorial Regional Hospital in Corner Brook is home to Canada’s largest geothermal system, which has set a precedent for modern infrastructure for both Newfoundland and Labrador and North America. The geothermal field is approximately 600 feet below the hospital’s parking lot, and provides 100 per cent of the ground… Read More…

  • Brightening Communities: LED Technology in Action

    Brightening Communities: LED Technology in Action

    August 15, 2024 By Alex Price, Brand & Planning Manager, Current LightingTechnical Contributor: Gary Steinberg, Senior System Manager (Outdoor LED Fixtures), Current Lighting As the landscape of Canadian cities continues to evolve, the importance of outdoor lighting cannot be overstated. From enhancing public safety to promoting economic activity and fostering a sense of community, well-planned… Read More…


Changing Scene

  • Schneider Electric Launches SMART Buildings Division to Drive Sustainable Building Innovation in Canada

    Schneider Electric Launches SMART Buildings Division to Drive Sustainable Building Innovation in Canada

    Schneider Electric is transforming its Digital Buildings business in Canada with the launch of the SMART Buildings Division. This evolution marks a strategic move to deliver comprehensive solutions and services that support building owners and operators in achieving their decarbonization and sustainability goals. The demand for smart buildings is surging, driven by a global shift… Read More…

  • Introducing Alan Bearden as Interim President of Southwire Canada

    Introducing Alan Bearden as Interim President of Southwire Canada

    September 4, 2024 Southwire Canada is pleased to announce that Alan Bearden has been appointed Interim President. In this role, Alan will provide leadership and guidance for Southwire’s Canada-based organization, ensuring continuity and driving growth during this transitional period. Alan Bearden brings a wealth of experience to the position, having joined Southwire in 2008. Over… Read More…

  • A Partnership Between Electromag Graybar Canada and Phoenix Contact

    A Partnership Between Electromag Graybar Canada and Phoenix Contact

    September 3, 2024 Electromag Graybar Canada, a pioneer in industrial automation solutions and pneumatic products, is excited to announce a partnership with Phoenix Contact, a global leader in electrification, networking, and industrial automation. This collaboration, which initially began in the Langley and Ontario branches, is now expanding to Quebec. The alliance aims to provide cutting-edge… Read More…

  • Sonepar Announces the Retirement of William (Bill) C. Smith, Electrozad Director of Transitional Business

    Sonepar Announces the Retirement of William (Bill) C. Smith, Electrozad Director of Transitional Business

    September 2, 2024 William (Bill) C. Smith, Director, Transitional Business of Electrozad Supply Company Limited announced his retirement as of August 30th, 2024 after 49 years of leadership. Bill began his electrical career working part-time at Electrozad Supply while completing a Sales & Marketing Program at St. Clair College.  After his first full-time position in… Read More…