Fixed Electrical HeatingPierre McDonald

Users of the Canadian Electrical Code, 23rd edition will see a completely re-written Section 62 covering fixed electric heating systems. Advances in new heating technologies as well as increases in electric heating efficiency at the point of use have seen growth in industrial, commercial and residential applications. Changes to Section 62 include these new applications as well as a complete re-organizing of existing requirements. Rules that duplicated requirements or were repeated for different installations have been combined.Significant entries have also been included within Appendix B to assist with clarification.This article will attempt to simplify the requirements and illustrate the total overall change within Section 62.

Heating technology

Fixed electric space heating refers to the application of providing heat to an enclosed space or room for the comfort of persons or animals, or simply to maintain a specific temperature required by products stored within that room.Electric heaters provide heat in a room by radiation, conduction or convection.Understanding these heating methods helps to understand installation requirements, including clearances.

Radiant heating is heat energy transferred in the form of electro magnetic radiation. A common example is the warmth of the sun.Fixtures generating radiant heat will have very specific clearances from combustible and non-combustible materials.

Convection heating is simply the movement of heat by air. This is also known as forced air. However, not all convection heating is forced air. The natural movement of air over a heating element causes hot air to rise within a room. The heated or hot air will eventually cool and fall back down to the floor, circulating through the heater and repeating this cycle.Fixtures producing convection heat will also have specific clearances from combustible and non-combustible materials.

Conduction heating is the transfer of heat energy between objects that are in physical contact with each other.This type of heating is common in industrial applications where tanks, piping and vessels must be heated to ensure their contents do not freeze.These heating technologies will have virtually no clearance requirements from the surfaces they are designed to heat. However, clearances from other adjacent surfaces may need to be observed.Additionally, a maximum temperature limit will come in to play with some applications.

Section 62: scope

Revisions to the scope of Section 62 now include all fixed heaters, including fixed electric space heating systems for rooms and similar areas, fixed surface heating systems, and fixed heating that is not considered as space heating or surface heating.Examples of these three heating systems have been tabulated and are listed in the Appendix B note to Rule 62-000 and include:

• central heating units
• baseboard heaters
• radiant heaters
• wall and ceiling heaters
• floor warming heaters
• pipe heating
• storage tank or vessel heating
• snow and/or ice melting
• Skin effect heating
• pipe internal heaters, often referred to as “gut” heating
• immersion heaters
• hot water tanks

General (100 Series) Rules

Several changes have been made to the General Rules (100 Series) of Section 62.Rules of a general nature that were scattered throughout the section have all been consolidated.Additionally, several rules that repeated themselves in the previous edition CE Code have been rewritten once for clarity.This simplifies the meaning and lets code users know that the rules specified under the General Rules apply to all heating installations except where otherwise specified.The following is a summary of the changes to the General Rules, 62-102 to 62-128.

• Heating devices shall be assembled and installed “following manufacturer instructions.”This is stated just once as opposed to several times as in previous editions of the code, Rule 62-102(1).
• CE Code Part ll standards require electrically conductive coverings, braids, etc. on all heaters. Rule 62-102(2) requires that these coverings be bonded to ground.
• Special Terminology (62-104 Definitions) includes standardized cable and panel definitions, and has changed “Fixture” to “Heating fixture.”The generic term “Heating device” includes all heaters and has added definitions forbare element water heater, dielectric heating, impedance heating, induction heating, and skin effect trace heating.
• Wet conditions are stated in AppendixB Note to Rule 62-106 as concrete slabs or masonry in direct contact with earth or drains, e.g., showers,but not where isolation measures are installed, e.g., a membrane.
• One requirement has been set for maximum temperature adjacent to combustible materials: 90oC, Rule 62-112.
• The previous requirement not allowing a flammable fluid to be heated above its flash point (62-118(3)) has been deleted.
• All ground fault protection requirements were consolidated into one general rule, (62-116), with exemptions for industrial establishments under certain conditions. Additional exemptions apply to heaters on Class 1 extra-low-voltage power circuits with an ungrounded secondary isolating transformer.
• A demand factor relaxation was added for cyclic loads.
• Updates were made to field repair, modification or assembly of series heating cable sets(62-126).

Space heating (200 Series)

These rules (62-200 to 62-222) have also seen several changes with edits tobetter match the topic area. The rules cover fixed electric space heating systems for heating rooms and similar areas, and now recognize surface heaters and wall heating. One of the significant changes includes the addition of Table 67, which identifies clearance requirements of installed heating systems. Temperature limits shown in Table 67 were derived from the Maximum Temperature Table in C22.2 No. 130, reproduced in Appendix B. Additionally, five diagrams (B62-1 to B62-5) were added to Appendix B,illustrating examples of clearances in residential applications. The maximum temperatures for heater contact with materials are

• 150oC for masonry, concrete, etc., 62-210(2)
• 90oC for combustible material, 62-112

The requirements for sauna heaters have also been included within the 200 Series (62-222) with a few changes.

Surface heating (300 Series)

The 300 series of rules (62-300 to 62-314) covers fixed surface heating systems for pipe heating, melting of snow or ice on roofs or concrete or asphalt surfaces, soil heating, and similar applications other than space heating. Substantial changes were made to applications of heating systems under sidewalks, driveways, and similar areas whereby the non-safety requirements (clearances, separations, wattages, etc.) associated with these installations were moved to the informative Appendix B, leaving the rules to address the safety related requirements. Other notable changes include:

• The 90oC Max Temp. requirement changed, applyingonly to adjacent combustible materials and now in the General (100) section.
• 750 V limit for parallel cables has been deleted (this is covered in the product standard).
• The requirement for marking has been changed to requirements for caution labels, with subrules added to define the frequency of these labels.
• Requirements for skin effect trace heating systemshave been added (62-314), including an Appendix Bnote and diagram (B62.6)

Other heating (400 Series)

Lastly, the 400 Series (62-400 to 62-410)was revised to bring the requirements for heating cable sets and heating panel set installed within pipes, ducts or vessels up to date. Pipeline resistance heating is now referred to as pipeline impedance heating, and several rules have been moved from Section 26 for infrared drying lamps, water storage tanks, dielectric and induction heating, and bare element water heaters.

Additional changes and the re-organization of Section 62 rules will continue to take place. Requirements are in the works for heating within hazardous locations as well as Induction heating. Advances will also take place with skin effect heating and impedance heating systems. With the changes to this 2015 CE Code, Section 62 is posed to accept new heating technologies and any new safety requirements. While this article covers a very general view of section 62, it is incumbent on the Code user to review all the changes and apply the rules accordingly. It should also be noted that while this 2015 CE Code is published and available, to date it has yet to be recognized by anyprovincial or territorial authority having jurisdiction (AHJ). Code users should contact their Inspection authority to determine when this code becomes law within you jurisdiction.

More from Pierre McDonald:
- Conductor Ampacities and Their Temperature Rating
- Code and Public Safety
- Establishing When the CE Code Becomes Mandatory
- UL Code Link
- CAN/ULC-S576-14, Standard for Mass Notification System Equipment and Accessories
- Canadian CE Code Changes: Section 20 and More
- Meeting National Building Code of Canada Requirements


 

Pierre McDonald, CET, is Senior Regulatory Affairs Representative/Répresentant Principal, Affaires Réglementaires, Underwriters Laboratories of Canada Inc. Based in St. Albert, AB, Pierre has been a member of the Canadian Electrical Code Part 1 technical committee as well as several subcommittees including serving as Chair of Sections 6 and 76 and as a member representing regulators on several other CSA committees. Pierre is still active with code development and interpretation.

 

Changing Scene

  • Prev
This month, IDEAL is challenging competitors to draw an Electrical Power One-Line Diagram ...
EngWorks Inc. and the Alberta Electrical Alliance have announced a strategic partnership as of May ...
David Collie, ESA’s President & CEO, signs the new Leadership Accord, proudly committed to ...
Electro-Federation Canada (EFC) represents electrical and automation manufacturers, distributors ...
Demand for electric vehicles in Canada keeps increasing; 68% of Canadians will consider ...
ESA is warning on potential electrical hazards associated with the replacement of metallic water ...
The Canadian Apprenticeship Forum (CAF-FCA) has released its latest labour market information ...
The Ontario government is introducing new measures to help tradespeople get their certification ...
MP Scott Duvall has introduced an amendment to the Income Tax Act regarding travel expenses for ...
George Brown College has partnered with Hilti (Canada) Corporation to help women build rewarding ...


 

ABB RoboticsABB Robotics is driving automation in the construction industry with new robotic automation solutions to address key challenges, including the need for more affordable and environmentally friendly housing and to reduce the environmental impact of construction, amidst a labor and skills shortage.

Robotic automation offers huge potential to enhance productivity, efficiency and manufacturing flexibility throughout the construction industry, including automating the fabrication of modular homes and building components off-site, robotic welding and material handling on building sites and robot 3D printing of houses and customized structures. 



Read More


 

Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion

 


 

Smart GridHarnessing Canada’s immense clean energy resources requires transformational investments to modernize our electricity grid. The Government of Canada is investing in renewable energy and upgrading the electricity grid to make clean, affordable electricity options more accessible in communities across Canada.

The Honourable Seamus O’Regan Jr., Minister of Natural Resources, today launched a $964-million program to support smart renewable energy and grid modernization projects that will lower emissions by investing in clean energy technologies, like wind, solar, storage, hydro, geothermal and tidal.

Read More

 


 



Trilliant Partners with the City of CowansvilleThe City of Cowansville in south-central Quebec is the largest city in the Brome-Missisquoi region, with more than 15,000 residents. Despite being a smaller-sized city, it is known as an economic and industrial hub.

It also has a strong focus on innovation and efficiency — as demonstrated by decisions such as the one it made in 2017 to use beet juice to help combat icy winter roads, allowing the City to reduce the amount of salt it was using, thereby saving money and decreasing the impact on the environment. 

 

 

Read More


 

Keith SonesBy Keith Sones

The writing was on the wall.  The closures would happen. But a lot of people were upset, and I was one of them. 

In the early 2000s, my family and I were living in a mainly rural (at least by city dweller standards) valley in south central British Columbia.  The West Kootenay region is known for its diverse outdoor recreation activities and as a great place to raise a family.  It has a proud industrial history, evidenced through the longstanding pulp mill, a massive lead zinc smelter a few miles away and several hydroelectric dams, all of it within spitting distance of the mighty Columbia River. 

Read More


 

Product News

  • Prev
Klein Tools introduces the new Magnetic Wire Puller, to help professionals quickly and easily fish ...
Siemens new 3VA molded case circuit breakers offer safe, efficient and variable application options ...
Hubbell’s illuminated plugs and connectors are the latest addition to the already broad line of ...
The ABV is a specification high bay that provides high performance and reliability. Available with ...
The Vive PowPak phase select dimming module is a radio frequency (RF) control that operates phase ...
6 functions in one pair of pliers. Multifunctional pliers for the electrical installation; to grip ...
With the ABB StarTeck® selector web app you can match cables with Teck fittings quickly and easily. ...
WPS Gen 4 wall pack series is a classic and familiar design integrated with modern LED technology ...
These new controllers offer indoor or outdoor ON/OFF, photocell, dimming, scene and color tuning ...
Eaton’s broad selection of Wi-Fi smart devices offer reliability with unbeatable ease of setup. ...

 

Lumenquad New VersionsLumenpulse has announced the release of two additional smaller sizes of the Lumenquad, a rectilinear projector for both outdoor and indoor environments. Developed for architectural applications such as lighting landscapes, highlighting details, pathways and monuments, the Lumenquad Small and Medium are compact, low-wattage, high-performance projectors, complementing the two existing products in the family.

The Lumenquad Small and Medium are the latest additions to a family of sleek, elegant, high-performance projectors that has already been validated with honours, including recognition in the PIA Awards in 2019, together with a Lux Awards for Exterior Luminaire of the Year in 2019. 

Read More


 

 

Wiha Lineman's Pliers and CrimpersWiha Insulated SoftFinish® Cushion Grip Pliers and Cutters are the standard for premium quality featuring ergonomic cushion grip handles for comfort and control, dual durometer construction for long-lasting durability, and handles directly molded to the tool steel for a permanent bond.

The grips feature a slip guard handle design for added protection at the front-end and raised rear-finger steps for easy opening at the back-end. Wiha Insulated SoftFinish® Cushion Grip Pliers and Cutters consist of premium quality tool steel for strength and durability and induction hardened cutting edges and jaws for superior sharpness and longevity. 

Read More


 

 

eLumigen Poultry Lamps - 2000K, 3000K & 5000KIdeal for rough service applications, the A19 & PAR Series are engineered for high efficiency, vibration resistance, shatter-resistance, elevated heat environments, and wet locations. These dimmable LED Lamps help reduce energy costs, labor costs, and the headaches of frequent lamp changes in tough applications.

eLumigen employs a unique 21-point validation process that goes above and beyond industry standards. Our lamps have been tested to survive levels of vibration exceeding 20G forces. Our unique temperature foldback design improves both safety and thermal management of our lamps. 

Read More


 

Peers & Profiles

  • Prev
Bryan Smith started his now 20-year career at the ground floor, so to speak, as a draftsperson and ...
From small construction to sophisticated industrial projects, House of Electrical Supplies has been ...
Kyle Manfredi is the owner of ARK Electrical alongside his wife, Shannon. Operating out of ...
Like most major events over the last year, the COVID-19 pandemic put serious restrictions on the ...
This past December Jennifer Green was honoured with Canada’s Most Powerful Women Top 100 Award for ...
“It was quite surprising,” said Stephanie Smith of being named EHRC’s Leader of the Year. ...
As an advanced networked lighting controls company serving the industrial and large commercial ...
Trilliant, an international provider of utility solutions for advanced metering and smart grid ...
For more than a century, ABB has been investing in Canadian technologies and products to support ...
Mackenzie Gillan, a bright young lady from Baysville, Ontario, tells us about how she learned ...


House of Electrical SuppliesFrom small construction to sophisticated industrial projects, House of Electrical Supplies has been servicing clients in the industrial, OEM, entertainment, and construction markets across the Greater Toronto Area for just over 40 years. The company has earned a reputation for providing a high-quality customer experience.

As per President Austin Brennan, their experienced and knowledgeable team can be depended upon in any situation to deliver quick and efficient service. On top of their product solutions — ranging from electrical, automation, safety, lighting and portable power distribution — 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2021 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil