The code is a comprehensive document. Sometimes, it can seem quite daunting to quickly find the information you need. In this current series of articles, I will provide a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook, but will hopefully provide some help in navigating while reading the code. Here in this issue: Section 20 — Flammable liquid and gasoline dispensing, service stations, garages, bulk storage plants, finishing processes, and aircraft hangars.

Section 20 amends or supplements the general requirements of the code. It provides specific rules for a number of special Class I, Hazardous Locations.

Section 20 uses the Zone classification system, but as with Section 18 additions or modifications to existing systems may use the Division system as in Annex J20 of Appendix J. The special terminology definitions used in Section 18 also apply to Section 20.

This section is divided into seven parts covering 

• gasoline dispensing and service stations
• propane vehicle fuel dispensing, container filling, and storage
• compressed natural gas refueling stations, compressors, and storage facilities
• commercial repair garages
• bulk storage plants
• finishing processes; and Aircraft hangars

Although requirements are similar for each facility, there are some differences so be sure to check the specific part you are considering.

There are some common rules that are the same for each location.

Hazardous areas

Each part contains a rule outlining the hazardous areas or locations for which that part applies. Wiring and equipment within the hazardous areas as defined in that part shall conform to Section 18 requirements. Some parts have additional requirements, so check the appropriate rule in that part. Notes in Appendix B, Tables 63, 64 and 69, Diagrams 4,5,6 and 10, and the CEC Handbook are very helpful in determining the hazardous areas in various parts.

Sealing

Rules 20-012, 20-038, 20-066, 20-108, 20-208, and 20-412 specify that seals are required in accordance with Section 18, and this includes horizontal as well as vertical boundaries of the hazardous locations. Additional sealing requirements may be contained in specific parts.

Bonding

Rules 20-014, 20-042, 20-070, 20-212, 20-314 and 20-422 require that all metal raceways and all non-current-carrying metal portions of fixed or portable equipment, regardless of voltage, are to be bonded to ground in accordance with Section 10.

Specific parts

Gasoline dispensing and service stations

Rules 20-002 to 20-014 apply to electrical apparatus and wiring installed in gasoline dispensing and service stations and other locations where gasoline or other similar volatile flammable liquids are dispensed or transferred to the fuel tanks of self-propelled vehicles. Other areas used as lubritoriums, service rooms and repair rooms, and offices, salesrooms, compressor rooms, and similar locations shall, with respect to electrical wiring and equipment, conform to Rules 20-100 to 20-112, which are in the Commercial repair garages part.

Propane dispensing, container filling, and storage

Rules 20-032 to 20-042 apply to locations in which propane is dispensed or transferred to the fuel tanks of self-propelled vehicles or to portable containers, and to locations in which propane is stored or transferred from rail cars or tanker vehicles to storage containers. There are some special terms for this subsection defined in Rule 20-032:

Container refill centre (propane service station) — a facility in which a dispensing system is installed.

Dispensing system — a system, consisting of tank, pump and motor, propane dispenser, and associated piping and supports, for the storage, metering, and dispensing of liquid propane into containers.

Filling plant (bulk plant) — a bulk propane storage, distribution and transfer facility.

Vehicle fuel dispenser — a propane dispenser, specifically for dispensing liquid propane by volume into containers.

Compressed gas and natural gas refueling stations, compressors, and storage facilities

Rules 20-062 to 20-070 apply to locations in which compressed natural gas is dispensed to the fuel tanks of self-propelled vehicles and to associated compressors and storage facilities. These rules, however, do not apply to vehicle refueling appliances installed in accordance with CSA B149.1 that do not have storage facilities.

Commercial repair garages

Rules 20-102 to 20-112 apply to commercial garages where vehicles powered by gasoline, propane, or other flammable fuels are serviced or repaired.

Bulk storage plants

Rules 20-202 to 20-212 apply to locations where gasoline or other similar volatile flammable liquids are stored in tanks having an aggregate capacity of one carload or more, and from which such products are distributed (usually by tank truck).

Finishing processes

Rules 20-302 to 20-314 apply where paints, lacquers, or other flammable finishes are regularly or frequently applied by spraying, dipping, brushing, or by other means, and where volatile flammable solvents or thinners are used or where readily ignitable deposits or residues from such paints, lacquers, or finishes may occur.

Aircraft hangars

Rules 20-402 to 20-422 apply to locations used for storage or servicing of aircraft in which gasoline, jet fuels or other volatile flammable liquids, or flammable gases are used, but shall not include those locations used exclusively for aircraft that have never contained such liquids or gases, or that have been drained and properly purged.

In the next instalment we will be discussing Section 22 — Locations in which corrosive liquids, vapours, or excessive moisture are likely to be present.

* The source for this series of articles is the Canadian Electrical Code, Part I, published by CSA.

William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

Nexans Webinar - Key 2021 Electrical Code Changes Impacting Wire and Cable

Nexans Free WebinarJoin NEXANS for a free webinar with Isaac Müller, Applications Engineer for Nexans as he reviews and discusses the changes to the 2021 Canadian Electrical Code related to wire and cable. This free webinar will take place Wed, Jan 27, 2021 2:00 PM - 3:00 PM EST

This webinar includes:
- Updated rules to protect cables (12-514,12-516)
- New conditions of use for wire & cable (Table 19)
- An opportunity to ask your questions

Click here to register today. 


 

Changing Scene

  • Prev
Organizers behind the MEET (Mechanical Electrical Electronic Technology) Show have announced its ...
Be sure not to miss your opportunity to participate at EDIST 2021 The Power of Resiliency, January ...
Teledyne Technologies Incorporated and FLIR Systems, Inc.jointly announced that they have entered ...
In today's ever changing Canadian work environment, an organization that wants to succeed at ...
B.C.’s building-sector businesses can tap into an additional $8 million for projects to ...
Rittal Systems Ltd., Canada would like to announce that Tim Rourke will be resigning as President, ...
In a fast-changing world, it can be hard to keep up with the latest developments in technology and ...
This recall involves Southwire branded coiled, pre-cut red electrical wire sold in shrink wrap ...
Jennifer Green, Director of Competitions and Young Women’s Initiatives at Skills Ontario, has been ...


With close to 400 exhibitors and more than 6,000 attendees from throughout Canada and the United States, MEET is the second-largest industry event of its type in Canada, and the largest trade event east of Montreal. Given the size and nature of the show and the travel that comes along with it, the COVID-19 pandemic has forced the rescheduling of the event several times.

Read More

 


Canadian Electrical Contractor Discussion Group

CECD Zac recetacleOne CECD group memeber recently posed a quick code question regarding some new arc fault requirements and powering a hallway receptical with a bedroom receptical. 

Go HERE to join the discussion

 

 

 

 

 

 

 



The Beard and the Respiratory Protection MaskHalf-masks and full-facepiece respirators require an optimal seal to guarantee their effectiveness, and the beard can impede it considerably.

DID YOU KNOW THAT A BEARD’S REGROWTH AS LITTLE AS ONE DAY OLD CAN AFFECT THE MASK’S SEAL IN PLACE?

What does it mean exactly?

Since many masks have been tested on different face types, the results of these tests vary considerably. However, it should be noted that in 100% of cases, after 7 days without shaving, the respiratory protection masks showed a leak of more than 1%. This means that the air inside the mask contained more than 1% of unwanted particles!

Read More


 

Product News

  • Prev
Providing high quality illumination, LytePro’s low profile design complements and blends in with ...
The 6590 Gaslight I is a large scale Victorian authentically detailed fixture which consists of a ...
The WaveLinx industrial high bay and low bay sensors offer passive infrared (PIR) occupancy with a ...
The Swidget Motion Sensor Insert* uses infrared radiation to detect whether someone or something ...
Standard extruded inside and outside corner LED tape mud-in channels. Aluminum construction. ...
Traditional style, cost-effective, DLC-listed wall pack offered in 42, 80, and 120 watts. The ...
Lumenwerx is pleased to launch the Via Weather Series, a new subgrouping composed of ...
SATCO continues to expand its wall pack selection with options that make installation flexible and ...
Milwaukee Tool has added to its lineup of hand tool solutions ...
The Littelfuse LS6 (available in 1000 and 500 V) and the LS6R (available in 1500 V) series are ...

 

Signify LytePro LED Wall Pack Gen 3Providing high quality illumination, LytePro’s low profile design complements and blends in with its surroundings. Available in 3 sizes, LytePro offers two optical distributions, multiple lumen packages, and is suitable for a range of mounting heights.

Lumen output ranges from 1,000 to 9,600 with efficacies up to 114 LPW, and all models are DLC qualified. The LPW32 even features button photocell, motion response, battery pack, and field adjustable wattage options.

Read More

 

 


 

SATCO CCT Selectable Wall PacksSATCO continues to expand its wall pack selection with options that make installation flexible and stock versatile. The latest additions in the line include the CCT Selectable Small Wall Pack and the CCT Selectable Compact Round Wall Pack.

 
The Small Wall Pack is perfect for light commercial uses such a smaller storage units and municipal lighting, as well as commercial Main Street buildings. As with all of the fixtures in this exterior family, these wall packs offer advanced features, are built durable and are able to withstand harsh, all-weather conditions.

 

Read More


 

 

Peers & Profiles

  • Prev
Trilliant, an international provider of utility solutions for advanced metering and smart grid ...
For more than a century, ABB has been investing in Canadian technologies and products to support ...
Mackenzie Gillan, a bright young lady from Baysville, Ontario, tells us about how she learned ...
Energy Efficient Lighting is a LED lighting manufacturer with nearly 30 years of industry ...
Dee Durant is an industrial electrician apprentice attending Conestoga College and an Ambassador ...
ECAO recently launched a new program called Future Leaders Advisory Council (FLAC). Their inaugural ...
At 14, Tom Miguel was sitting in the counselor’s office of Silverthorn Collegiate Institute in ...
Meredith Halfpenny is a Wind Site Technician with Boralex where she inspects, maintains, and ...
Rutul Bhavsar is a final year Electrical Engineering student at Mohawk College. He recently ...
Shannon Tymosko is a first-year apprentice with IBEW (International Brotherhood of Electrical ...


Libra Smart MeterBy Blake Marchand

Trilliant, an international provider of utility solutions for advanced metering and smart grid systems, recently announced a custom-made product for the North American market with the release of its Trilliant Libra Series Edge-Ready Smart Electric Meter.


The meter’s technology will allow utilities to enter the connectivity sphere by providing peer-to-peer data acquisition and analytics, while enabling new energy management features that benefit both customer and utility. 

 

Read More


 

Copper $US Dollar price per pound

Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2021 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil