Avoiding and Resolving Issues with Products That Don’t Dim as Expected

Controls

Sept 16, 2018

With the right combination of dimmer and solid-state driver for LED products, dimming performance can achieve excellent results from 100% all the way to dark, smoothly and predictably. However, when the combination is wrong, many undesirable effects may occur, such as flashing, pulsing, flickering, or fluttering. Part 1 explored some of these behaviours. Here in Part 2, several potential causes and solutions.

At the top of the list is to ensure that the dimmer is properly connected and matches the driver being controlled. Utilizing 0-10V controls on 1-10V drivers can cause issues at low dim settings, specifically when on-off functionality is included. 1-10V luminaires on 0-10V dimmers may flash when turned on/off or will fail to turn off completely without cutting incoming power.

There are also two types of 0-10V dimming: voltage sourcing and current sinking. For entertainment control applications, it is possible that the control will use voltage sourcing, where the dimming system provides the low voltage control signal to the driver. For all architectural controls, current sinking is used, where the luminaires provide the low voltage signal for the control to act upon. Mixing these two up will result in no dimming response at all. Insure that the driver and dimmer are in compliance with IEC60929, which specifies both the voltage and current characteristics of architectural dimming controls. 

Connecting line voltage dimmers demands that the type of dimmer match the driver employed. Triac dimmable products will generally function with Triac (leading edge) or ELV (trailing edge) dimmers, while trailing edge products will exhibit flickering and sudden dimmer responses when connected to Triac dimmers. For the most part, use of LV (designed for magnetic transformer loads) is not recommended, as the dimmer function can be unpredictable. Line voltage dimmers are available from so many providers, with a wide range of specification, causing a range of issues that cannot be described fully here.

As a proactive measure, selecting products that are designed within IEC TR 63036:2016(E) which describes standardized forms of phase cut dimming. The only sure method for assuring compatibility is to test the dimmer with the intended load to expose any undesirable reaction. Driver and luminaire manufacturers may also provide lists of pre-tested dimmers found compatible. For diagnosing field problems, having a known functioning dimmer on hand to install and compare to a product causing field issues can go a long way toward solving an issue quickly. 

Wiring problems are generally diagnosed by disconnecting the dimmer controls and verifying luminaire function at full power. If this resolves undesirable dimming effects, the next step is to test different dimmers on the circuit in order to eliminate dimmer control incompatibility issues. If the problem persists, it will be necessary to remove a sample luminaire and attempt to isolate the driver itself as a cause separate of the dimmer, or compatibility issues with the dimmer. This requires the participation of the manufacturer, to avoid any possible miss-wiring of luminaires that might void warranties or cause failures the manufacturer will not accept as their responsibility.

Luminaire design issues can also become evident when dimmed. Generally, when an LED luminaire flashes, either at start up or at some point when dimmed, the issue can be traced to a low forward voltage condition, where the LED being powered is not producing enough voltage drop for the driver to function properly. Many drivers will flash, or strobe at low frequencies, indicating this condition. Others may simply stop operating at some point when dimmed. This can only be resolved by the luminaire manufacturer, in order to ascertain whether a component within the system is the cause, or some other issue has arisen in manufacturing that was not discovered. It is worth noting that dimming malfunctions due to internal circuit voltage problems are more common with 277V systems than at 120V. Further, during construction, temporary power is often outside the standard voltage specification, which can cause dimming issues that disappear once more reliable permanent power is connected. 

Flickering at either 120Hz or 60Hz is another common dimming complaint. This is most frequently present in low quality line voltage, phase cut dimming controls connected to low cost driver components. This is not a field condition, it is a product issue that should be addressed during product selection phase. 

Fluttering of light levels when a dimmer is moved through its range is often caused by low cost dimmers that have too few steps. Most electronic dimmers utilize some form of digital circuiting that steps light output down from full to minimum dim setting. To avoid this, quality dimmers utilize a large number of sampling steps, that are imperceptible to the operator. Low cost products may use fewer samples, creating a sense of flickering steps as the dimmer is actuated. This can exist in manual dimmers as well as electronic control systems.

Avoiding field issues is the first and best strategy when applying dimming of luminaires. A little effort put into testing samples, verifying compliance with standards, or verifying compatibility with manufacturers is an essential first wall of defence. With this in hand, field problems can then be assumed to be extraneous to the product interaction, leaving field wiring as the first issue to double check. After that, any issues can be boiled down to products not performing to manufacturer standards, which is then used to recruit them into solving field issues experienced. When expectations are realistic, products qualified through specification and/or testing, and installed verified to be complete and correct, there should be no field issues to resolve.

Kevin Willmorth has been involved with lighting since 1981. His experience includes electrical system design, lighting design consulting, product design, marketing, business strategy, and editorial writing. His past positions include positions include owner of a lighting design consultancy, VP of Design and Marketing for Kim, Winona, and Visa Lighting, VP and Director of Product Management Renaissance Lighting, and VP of Design – Lighting for Atlandia Design. He currently owns Lumenique, LLC, offering product design, prototype development, testing, and strategic consulting to manufacturers, application design and technology evaluation for building owners, and Tasca, a small industrial task lighting manufacturing firm. He is also Editor for SSL content in all Construction business media publications including Architectural SSL, Architectural Products, NZB, and Illuminate; kwillmorth@lumenique.com; www.lumenique.com

This article was first published online by the Lighting Controls Association: http://lightingcontrolsassociation.org/2018/07/06/avoiding-and-resolving-issues-with-products-that-dont-dim-as-expected/

Photo courtesy of Eduardo Silva Barbosa on Pixabay

Related Articles


Latest Articles

  • Stephanie Medeiros on EV Infrastructure in Canada, Innovative Technologies, Well-Planned Charging Networks, & Commercial Fleets

    Stephanie Medeiros on EV Infrastructure in Canada, Innovative Technologies, Well-Planned Charging Networks, & Commercial Fleets

    September 3, 2026 By Blake Marchand In this Q&A with Stephanie Medeiros, the Head of Mobility at Schneider Electric Canada provides insight into her perspective on EV charging infrastructure in Canada, factors that will contribute to growing EV adoption, grid modernization for commercial fleets, the role of Vehicle-to-Grid and other innovative approaches to electrification. The focus of… Read More…

  • LEDVANCE: Understanding Light Beam Angles

    LEDVANCE: Understanding Light Beam Angles

    September 3, 2026 Light Beam Angles: How It Affects Different Types of Lighting, Where It Is Applied & What to Consider When Choosing the Right One Beam angle is important in lighting design. It determines how light spreads within a space and influences both functionality and atmosphere. By understanding beam angles, you can achieve both… Read More…

  • ITC 101 Series: Why Certifications (UL, CSA) Matter in Industrial Components

    ITC 101 Series: Why Certifications (UL, CSA) Matter in Industrial Components

    September 2, 2026 By ITC Electrical Components When selecting industrial electrical components, certification is more than a logo on a datasheet. A certification mark indicates that a product or component has been independently evaluated against specified requirements for its intended market. In North America, selecting products with the appropriate certification can affect regulatory acceptance, equipment… Read More…

  • Project Spotlight: Leigh Square Fountain

    Project Spotlight: Leigh Square Fountain

    September 2, 2026 In spring 2025, the City of Port Coquitlam unveiled a transformed Leigh Square, reimagined as a vibrant, accessible, and welcoming gathering place in the heart of downtown. At the heart of the renewed plaza, a Bellagio-style programmable dancing fountain is integrated directly into the paving—three interlocking rings where jets rise, fall, and… Read More…


Changing Scene

  • 2026 Ontario Apprenticeship Awards Call for Nominations

    2026 Ontario Apprenticeship Awards Call for Nominations

    September 3, 2026 Skilled Trades Ontario is proud to open nominations for the 2026 Ontario Apprenticeship Awards, recognizing outstanding apprentices, journeypersons, organizations and skilled trades leaders who are helping strengthen Ontario’s apprenticeship system. Award recipients will be announced at the Ontario Apprenticeship Summit on November 4, 2026, at the Toronto Congress Centre. Nominations must be submitted… Read More…

  • Bartle & Gibson Announces New Partnership with Hubbell Canada

    Bartle & Gibson Announces New Partnership with Hubbell Canada

    September 3, 2026 Bartle & Gibson Co. Ltd., an Alberta-based premier plumbing, heating and electrical distributor and Hubbell Canada have announced a new regional partnership enabling increased access to Hubbell Canada’s end-to-end electrical product portfolio across Western Canada. “With our strong presence in the west through 31 branches and counting located in Alberta, Saskatchewan, British… Read More…

  • Bartle & Gibson Opens Salmon Arm Location

    Bartle & Gibson Opens Salmon Arm Location

    September 3, 2026 Bartle & Gibson opened their new Salmon Arm location on July 20th. The Salmon Arm location features: This site is strategically positioned in the city of Salmon Arm, located near to the busy Picadilly Mall.  Salmon Arm branch is located at: 621- 10 Street SW Salmon ARM, BC V1E 1T1 Photo Source Read More…

  • MacKinnon Magnetics Announces Partnership with Resilient Sales Corporation in Northeastern Ontario

    MacKinnon Magnetics Announces Partnership with Resilient Sales Corporation in Northeastern Ontario

    September 3, 2026 MacKinnon Magnetics is pleased to welcome Resilient Sales Corporation as their newest sales agency partner. Resilient Sales will represent MacKinnon Magnetics across Northeastern Ontario, including the Districts of Muskoka and Parry Sound. Key markets include Sudbury, North Bay, Timmins, Kirkland Lake, Sault Ste. Marie, Huntsville, Bracebridge and Parry Sound. “This partnership expands… Read More…