Specifying Transformers for Hazardous Locations

Encapsulated Transformers

Mar 18, 2019

There are many requirements to meet when specifying transformers, such as basic performance parameters that include kVA, low and high voltage ratings, line frequency, etc. One must also consider the environment in which the transformer will be used. It is common in many industrial locations to find hazardous materials such as flammable liquids, gasses, vapors or combustible dusts in sufficient concentration to produce an explosion or fire. Electrical equipment installed in such a classified location must be designed, and tested, to minimize the risk of an explosion. These specially designed products ensure that sufficient energy is not available to ignite the specific hazardous material(s) present in the classified location. Electrical equipment rated for use in hazardous locations is typically more expensive, but the higher performance trade-off makes them valuable.

Simply providing a transformer to install in a hazardous location area is not enough; one must also consider other critical application criteria such as available short circuit current (impacted by transformer impedance), ease of installation and accessibility, as well as ongoing maintenance cost.

Regulations related to hazardous locations have been formulated by the International Electrotechnical Commission (IEC), and they use a Zone classification system. In North America, both the US National Electrical Code (NEC) and the Canadian Electrical Code (CEC) now also recognise the use of a Zone System for classification of hazardous areas.

HPS Titan N

HPS Titan N is designed in accordance to North American hazardous location regulations. The product has been tested to ensure the required uniform safety standards for electrical equipment used in hazardous locations have been met.
HPS Titan® N is currently approved for Class 1, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC, T3 Hazardous Locations as defined by ANSI/ISA 12.12.10, UL 5085-1 and UL5085-2. IECex approval is in progress and will be available in 2019.

Extensive Temperature Range Flexibility

One of the most important considerations in a hazardous area is the temperature rating of the electrical equipment. The surface temperature of any parts that may be exposed to the hazardous atmosphere must be tested so that it does not exceed 80% of the auto-ignition temperature of the specific gas or vapor in the area where the equipment is intended to be installed. The HPS Titan® N standard designs are flexible, and can be installed in locations with a wide range of ambient and application temperature performance requirements (exact temperature performance may vary by kVA in some cases).

In 40°C ambient temperature:
o T3C temperature performance is available with 80°C and 95°C rise units
o T3A temperature performance is achieved with 115°C units

In 50°C ambient temperature:
o T3C temperature performance is available with 80°C rise units
o T3A temperature performance is achieved with 95°C and 115°C rise units

The broad temperature performance capabilities of the Titan N makes this transformer adaptable to a variety of applications.

Rugged Construction

HPS Titan® N has a core and coil that is completely encapsulated in epoxy and silica. This construction physically separates and isolates electrical parts, and helps reduce surface temperature. This minimizes the possibility that it can ignite hazardous materials within the surrounding area. Specialized areas, such as an offshore location, are addressed with enclosures made from more durable stainless steel.

Prevent Critical Electrical Conditions

HPS Titan N has an innovative design that limits electrical inrush and short circuit currents, minimizes the impact of voltage spikes and maintains the external surface temperature at safe levels under bothnormal operation and fault conditions. The impedance of a transformer determines the maximum current during a short circuit fault. The lower the fault current, the lower the interrupting capacity of a circuit breaker or fuse employed to protect the primary connection of the transformer. HPS Titan N has higher impedance levels to help lower fault current levels, requiring less expensive lower AIC rated circuit breakers or fuses.

Inrush current at energization is a source of much frustration for field operators when it immediately trips a circuit breaker or blows a fuse. Was it genuine fault? Is it risky to energise again? Is there something else at play? Determining these answers before re-energizing the equipment takes time and costs money. Titan N reduces the potential for the nuisance tripping of circuit breakers or blown fuses with significantly lower energization inrush currents Mother Nature is unpredictable and has it own rules. A lightening strike or other utility power line disturbances can cause voltage spikes. This can cause transformer and other equipment damage. With a standard 10kV BIL protection HPS Titan ® N can minimize the impact of voltage spikes.

Lower Installation & Maintenance Costs 

There are many hidden costs in the installation process of a transformer. When accessing the wiring compartment of transformer, you need to account for time necessary to physically open the panel and create proper cable connections. With this in mind, HPS has designed the enclosure with a front opening removable hinged door with simple, secure screw clips. These adjustable screw clips provide labour savings and fast access to the wiring compartment. Their captive design also prevents their loss when opening the compartment. The wiring compartment of HPS Titan N is large and allows for easier cable routing as well as bigger wire bending radius. If periodic maintenance is required, it is quite easy to gain access to the wiring compartment.

HPS Titan N easily adapts to various applications instead of the customer altering the application to fit with the transformer. Titan ® N will be available for sale on January 9th, 2019.

For more information visit https://www.hammondpowersolutions.com/product/hpstitann/

Related Articles


Latest Articles

  • CAF-FCA Provides Recomendations on Apprenticeship Investment

    CAF-FCA Provides Recomendations on Apprenticeship Investment

    April 13, 2025 CAF-FCA have provided an outline of actionable recommendations—developed through national consultation—to enhance accessibility, reduce financial barriers, and better align apprenticeship training with industry needs. Source Read More…

  • New Report: Preparing Alberta’s Buildings for Severe Weather

    New Report: Preparing Alberta’s Buildings for Severe Weather

    April 13, 2025 Alberta is facing more severe weather events, with rising temperatures, wildfires, and more frequent extreme storms threatening homes and businesses. Our report, Preparing Alberta’s Buildings for Severe Weather−written in partnership with the Alberta Ecotrust Retrofit Accelerator program−highlights the need for deep retrofits to ensure the province’s buildings can withstand these changing conditions. Four… Read More…

  • CCA Bulletin: Managing Tariff Risks in Construction Projects

    CCA Bulletin: Managing Tariff Risks in Construction Projects

    April 13, 2025 This bulletin was prepared by select members of the Canadian Construction Association’s (CCA) General Contractors National Advisory Council. Its purpose is to assess the potential impacts of tariffs and counter-tariffs on general contractors in Canada focusing specifically on: In both areas, the bulletin explores both upstream and downstream impacts – examining how… Read More…

  • Video: ABB Installation Products Proudly Powering Canada

    Video: ABB Installation Products Proudly Powering Canada

    April 7, 2024 From coast to coast, ABB Installation Products is built by Canadians, for Canadians—delivering high-quality solutions that power industries and support communities across the country. Read More…


Changing Scene

  • PEI’s First Net Zero Ready School Officially Opens

    PEI’s First Net Zero Ready School Officially Opens

    April 13, 2025 Island students, their families and the Sherwood school community came together today to celebrate the opening of PEI’s first net zero ready school. The new Sherwood Elementary School, built next to the former school, offers over 82,000 square feet of space with many innovative features to promote enhanced learning experiences for up… Read More…

  • Nova Scotia Invests to Connect Nova Scotians to Skilled Trades

    Nova Scotia Invests to Connect Nova Scotians to Skilled Trades

    April 13, 2025 The Province is helping more Nova Scotians explore and connect to careers in skilled trades through a $10-million investment in the construction industry. The investment will support more skilled trades training through three key initiatives: “Nova Scotia needs more skilled trades professionals to support our growing economy and to build the homes,… Read More…

  • PEI Tables Bill Aimed to Eliminate Trade and Labour Barriers

    PEI Tables Bill Aimed to Eliminate Trade and Labour Barriers

    April 13, 2025 Hon. Rob Lantz, Premier of Prince Edward Island, introduced the Interprovincial Trade & Mobility Act in the provincial legislature. This bill will allow Prince Edward Island to eliminate unnecessary barriers to trade and labour mobility with reciprocating jurisdictions.   The Bill will accept provincial inspections and standards on goods coming from a… Read More…

  • PEI Minimum Wage Set to Increase

    PEI Minimum Wage Set to Increase

    April 13, 2025 Minimum wage in Prince Edward Island will increase incrementally to $17 per hour by April 1, 2026.  The Employment Standards Board reviews minimum wage annually and provides their recommendation to government.  Go HERE for more information Source Read More…