Test & Measurement Safety Considerations

Test & Measurement Safety

May 3, 2021

By Blake Marchand

When troubleshooting electrical issues its important to recognize electrical shock is a result of current (not voltage, although the amount of voltage is a factor) and that it takes a fairly low amount of current to result in injury.

“Electricity needs to be respected. Many times, in our industry that is not the case,” says Fluke sales engineer, Curt Geeting. It is human nature to become desensitized to risk the more we are exposed to it. So, it may not be a matter of negligence as much as complacency when it comes to ‘respecting’ electricity. Or it may be a matter of probability. You’re working with it everyday over a long period of time, mistakes are bound to happen.

Similarly, Terry Becker (P.Eng., CESCP, IEEE Senior Member) notes that ‘high voltage’ does not always equate to ‘high risk’. Low voltage electrical equipment may present a higher or equal risk without the appropriate application of hierarchy risk procedures.

“In the CSA Z462 Workplace electrical safety Standard it doesn’t use the voltage level of electrical equipment to define low risk, medium risk, high risk or extreme risk/danger. CSA Z462 Clause 4.1.7.8 Risk assessment procedure outlines three requirements in completing a risk assessment: identify hazards; assess risks; and implement risk control according to the hierarchy of risk control methods to eliminate exposure or reduce risk to as low as reasonably practicable.”

Becker explains that, “The starting point is the work task description.” CSA Z462 provides a table (Table 2) to help estimate the likelihood of arc flash incident occurring for AC and DC systems. “It provides thirty-one (31) discrete energized electrical work tasks. The voltage of the electrical equipment that will be worked on is secondary and is used to define if an abnormal arcing fault can be sustained and lead to an arc flash occurring. The voltage also determines if a shock hazard exposure can occur. The third consideration in completing the risk assessment procedure is the actual electrical equipment that the energized electrical work task will be performed on.  Following this sequence, a qualitative risk assessment for the Job and discrete work task(s) will be used to determine the residual risk level based on the energized electrical work task description first.”

Causes of arc flash and shock include: loose panel wiring, screws or fasteners that fall into an unsecured panel against a live bus, hand tools shorted across two phases, incorrect test probes, misuse of measurement stools.

With respect to the latter, Geeting says issues occur when, “Measuring across phases with an inline amp meter, creating a short circuit. Measuring continuity on a live circuit with a tool that cannot withstand full voltage. Accidental shorting of phases with a test lead tip that is too long of the safety category.”

Most electricians will require a CAT III rating within the 600 volt range.

When detecting the absence of voltage, often the first device used is a non-contact voltage detector. Even though you are not physically touching equipment the appropriate CAT rating needs to be observed and PPE still needs to be worn.

To verify it is operating properly, Geeting notes, you should use the live-dead-live method by finding an associated live circuit to test and verify the operation of the meter, then “Go into the target circuit, which we’re assuming are de-energized and are looking to make sure that it is dead or de-energized. And then we go back to the live circuit again. So, its the three-point method by which to verify my contact or non-contact voltage tester is in fact working.”

“The idea is, obviously, I’m trying to have 100% confidence that circuit is in fact de-energized. And this is the easiest way to figure that out and know that my meter is working and telling me the truth.”

There are instances where you won’t have a reference point to verify the tester. There are handheld units that provide a regulated/fixed AC or DC output voltage, which can be used to verify testers, as well as multimeters and clampmeters.

Test leads may be the biggest weakness in your multimeter systems. Something as simple as wrapping them around your meter can cause issues, “pulling on the leads in any direction and wrapping them around your meter tightly, you’re basically going to be breaking the small conductors inside those wires,” says Geeting.

It’s important to confirm the meter has shrouded connectors and finger guards, the insulator is not pulled away and the probe tip isn’t loose, broken, or blown off. Along with ensuring the meter is appropriately rated and designed for the application.

It is also worth noting a few best practices that have been noted by a couple of contractors and industry experts… work on de-energized circuits whenever possible. Maintain your tools and PPE. If possible, don’t work alone. Connect the grounded lead, then hot and disconnect the hot lead before the grounded lead. Use live-dead-live test method.

Given that its not always possible to fully eliminate risk and given the number of hours electricians put it in on the job, its important to recognized mistakes will be made. And often, the most obvious things are the easiest for us to overlook. In this context, the importance of reviewing and following basic procedure and being diligent about the best practices you’ve developed throughout your career can’t be overstated.

Related Articles


Latest Articles

  • Winnipeg Information Bulletin: Low-Risk Voice, Data, Video & Security System Installations

    Winnipeg Information Bulletin: Low-Risk Voice, Data, Video & Security System Installations

    September 17, 2026 Certain types of installations may qualify for a low-risk voice, data, video (VDV) and security system electrical permit. For information related to regular VDV/security system installations, see winnipeg.ca/vdvsystems. Applications must be submitted through Permits Online. Electrical permits and inspections are needed for certain installations of security and similar alarm systems. This makes… Read More…

  • What Type of Outdoor Light Do I Need for My Application?

    What Type of Outdoor Light Do I Need for My Application?

    September 17, 2026 By Stanpro The right outdoor light starts with the space you need to illuminate and how that space is used. For commercial projects, parking lots and large exterior areas point toward area lights; entrances and building perimeters toward wall-mounted or security lighting; signs, facades and targeted areas toward flood lights; pathways toward… Read More…

  • Alberta Employers and Tradespeople Share their Perspectives

    Alberta Employers and Tradespeople Share their Perspectives

    September 16, 2026 In Alberta’s skilled trades labour market employers and tradespeople are facing growing pressure from tariffs, rising costs, hiring challenges and labour mobility barriers. CAF-FCA’s new report, Hiring, Mobility and Needed Supports: Alberta Employers and Tradespeople Share Their Perspectives, takes a closer look at what’s happening on the ground. Based on surveys of… Read More…

  • Goal Zero YETI 3000X Power Stations Recalled due to Fire and Burn Hazards

    Goal Zero YETI 3000X Power Stations Recalled due to Fire and Burn Hazards

    September 16, 2026 This recall involves Goal Zero YETI 3000X power stations. The silver and black portable power stations measure about 62 centimetres (24.4 inches) high, 47 centimetres (18.5 inches) wide, 57 centimetres (22.3 inches) deep and weigh approximately 42 kilograms (92 pounds). The power stations have yellow handles and a digital display at the… Read More…


Changing Scene

  • LEDVANCE Canada Marks 10 Years of Innovation and Growth and Looks Ahead to Its Next Chapter in the Canadian Market

    LEDVANCE Canada Marks 10 Years of Innovation and Growth and Looks Ahead to Its Next Chapter in the Canadian Market

    September 25, 2026 From legacy lighting leader to solutions partner, LEDVANCE is entering its next decade with a clear focus on Canadian customers, communities, and market needs LEDVANCE Canada is marking the 10th anniversary of LEDVANCE as an independent brand by celebrating a decade of growth, customer partnerships, and continued investment in solutions designed around… Read More…

  • EFC Welcomes Patrick McManus as Incoming President & CEO

    EFC Welcomes Patrick McManus as Incoming President & CEO

    September 25, 2026 Electro-Federation Canada (EFC) is pleased to announce the appointment of Patrick McManus as President & CEO, effective October 13, 2026. McManus will succeed Carol McGlogan, who is retiring following 10 years with EFC. McGlogan will remain with the organization through the end of 2026 to support a smooth leadership transition. McManus is… Read More…

  • Innovair Solutions Acquires TRM Heating Cables

    Innovair Solutions Acquires TRM Heating Cables

    September 18, 2026 Innovair Solutions has announced the acquisition of TRM Heating Cables, a Toronto-based Canadian company specializing in heating cables for commercial and industrial applications. Founded in 2001, TRM has built strong technical expertise in the sale and installation of specialized products, including self-regulating cables, mineral-insulated cables and electric floor heating systems. The company… Read More…

  • Electrical Safety Authority Honours Leaders Helping Build a Safer, More Electrified Future

    Electrical Safety Authority Honours Leaders Helping Build a Safer, More Electrified Future

    September 17, 2026 From preparing the next generation of skilled workers to supporting one of the world’s largest sporting events, this year’s recipients demonstrate how electrical safety supports Ontario’s future As Ontario electrifies homes, transportation and industry, the Electrical Safety Authority (ESA) has recognized the organizations and individuals helping ensure safety keeps pace with that… Read More…