Arc Flash Alphabet Soup: Understanding the Hazard Behind the Acronyms and Technical Terms (Part 1)

Arcflash Alphabet Soup

Jim Pollard

Part 1 – Basic Terminology

Arc flash, a type of electrical explosion, is one of the most complex workplace risks that exist. It is often described using technical terminology and acronyms. Below are the most important ones with simple explanation.

 

 

 

 

 BASIC INDUSTRY TERMINOLOGY

 Technical Terminology  Simple Explanation
 CSA Z462 and NFPA 70E  Workplace electrical safety standards for Canada (CSA) and the United States (NFPA). These best practice standards are technically harmonized and follow the same revision cycle (every 3 years).
 Arc flash PPE  Personal protective equipment (PPE) designed and tested to provide protection from the heat created by an arc flash hazard.
 Calories per cm2   Measurement of heat imposed on a surface area that is used to describe both the heat from an arc flash hazard (incident energy) and the protection provided by arc flash PPE (arc ratings). 
 Incident energy      Heat created by an arc flash measured as cal/cm2 (calories per square centimetre). Incident energy can be estimated using engineering calculations.
 Arc flash risk assessment  A requirement in CSA Z462 or NFPA 70E used as a process of identifying if an arc flash hazard exists; if yes, determine safety related work practices, arc flash boundary and the arc flash PPE required.
 Hazard/risk category (HRC)  Old method that is no longer relevant, which involved using tables from CSAZ462 or NFPA 70E to select arc flash and shock PPE for various work tasks and equipment.
 Arc flash PPE category  New method of using the tables from CSA Z462 or NFPA 70E to identify when arc flash PPE is required, and if required to select arc flash PPE based on different types of equipment.
 Detailed equipment label  Applied to electrical equipment to communicate important information related to the arc flash and shock hazards. Either the incident energy or the arc flash PPE category (but not both) is used to identify the potential arc flash hazard severity.
 Arc ratings  The protection provided by protective clothing and other types of PPE from the heat (incident energy) created by an arc flash. Determined by testing and reported on the product label.
 Types of arc ratings  Arc thermal performance value (ATPV): expressed using cal/cm2 to identify the incident energy level at which there is a 50% probability of sufficient heat transfer to cause the onset of a second-degree skin burn injury. 
   • Breakopen threshold energy (Ebt): expressed using cal/cm2 that identifies the incident energy level at which there is a 50% probability of the formation of holes or tears in the garment layer closest to the skin.

Jim Pollard is a member of several technical committees, including CSA Z462. He is the owner of Unlimited PPE in Stoney Creek, Ont., and can be reached at jim@unlimitedppe.com or (905) 573-0300.

Reprinted by permission of Canadian Occupational Safety © Thomson Reuters Canada Ltd., April/May 2015, Toronto, Ontario, 1-800-387-5164. Web: www.cos-mag.com.

Related Articles


Latest Articles


Changing Scene

  • BC Hydro Making it Easier and More Affordable to Connect New Homes

    BC Hydro Making it Easier and More Affordable to Connect New Homes

    July 24, 2025 BC Hydro is supporting the construction of new housing developments in growing communities by advancing changes to streamline upgrades and reducing the cost of new customer connections to BC Hydro’s electricity grid. “As communities across B.C. grow, so does the need for essential housing. We are committed to ensuring we’re ready to… Read More…

  • Mitrex Sets Record with Largest BIPV Solar Panel Mural at SunRise Residential in Edmonton

    Mitrex Sets Record with Largest BIPV Solar Panel Mural at SunRise Residential in Edmonton

    July 22, 2025 Building-Integrated Photovoltaics (BIPV) manufacturer, Mitrex proudly announces that its transformative SunRise Residential project in Edmonton, Alberta, has earned the Guinness World Record for the largest solar panel mural globally. This landmark project showcases Mitrex’s innovative BIPV solar panels, blending cutting-edge solar technology with vibrant cultural artistry to redefine sustainable architecture. Sustainable Architecture with BIPV Spanning over 30,000 square feet, the Mitrex eFacade PRO plus… Read More…

  • Nexans Unveils a Cable Made with 100% Recycled Materials

    Nexans Unveils a Cable Made with 100% Recycled Materials

    July 24, 2025 Nexans has reached a major milestone in its sustainability journey by developing a prototype cable made entirely from recycled materials — a first in the company’s history. This innovation combines technical performance, industrial feasibility, and a drastically reduced environmental footprint, marking a decisive step forward in circular economy. A cross-continental success story… Read More…

  • EFC Welcomes New Manufacturer Member: MGM Transformers

    EFC Welcomes New Manufacturer Member: MGM Transformers

    July 24, 2025 Since 1974, MGM Transformers has produced tough and trusted transformers designed to get the job done right. As a leading manufacturer, the company employs a highly experienced and dedicated engineering team that excels in custom designs. MGM Transformers is committed to excellent quality and service, offering industry-leading lead times and exceptional customer service. MGM Transformers specializes… Read More…