Arc Flash Alphabet Soup: Understanding the Hazard Behind the Acronyms and Technical Terms (Part 1)

Arcflash Alphabet Soup

Jim Pollard

Part 1 – Basic Terminology

Arc flash, a type of electrical explosion, is one of the most complex workplace risks that exist. It is often described using technical terminology and acronyms. Below are the most important ones with simple explanation.

 

 

 

 

 BASIC INDUSTRY TERMINOLOGY

 Technical Terminology  Simple Explanation
 CSA Z462 and NFPA 70E  Workplace electrical safety standards for Canada (CSA) and the United States (NFPA). These best practice standards are technically harmonized and follow the same revision cycle (every 3 years).
 Arc flash PPE  Personal protective equipment (PPE) designed and tested to provide protection from the heat created by an arc flash hazard.
 Calories per cm2   Measurement of heat imposed on a surface area that is used to describe both the heat from an arc flash hazard (incident energy) and the protection provided by arc flash PPE (arc ratings). 
 Incident energy      Heat created by an arc flash measured as cal/cm2 (calories per square centimetre). Incident energy can be estimated using engineering calculations.
 Arc flash risk assessment  A requirement in CSA Z462 or NFPA 70E used as a process of identifying if an arc flash hazard exists; if yes, determine safety related work practices, arc flash boundary and the arc flash PPE required.
 Hazard/risk category (HRC)  Old method that is no longer relevant, which involved using tables from CSAZ462 or NFPA 70E to select arc flash and shock PPE for various work tasks and equipment.
 Arc flash PPE category  New method of using the tables from CSA Z462 or NFPA 70E to identify when arc flash PPE is required, and if required to select arc flash PPE based on different types of equipment.
 Detailed equipment label  Applied to electrical equipment to communicate important information related to the arc flash and shock hazards. Either the incident energy or the arc flash PPE category (but not both) is used to identify the potential arc flash hazard severity.
 Arc ratings  The protection provided by protective clothing and other types of PPE from the heat (incident energy) created by an arc flash. Determined by testing and reported on the product label.
 Types of arc ratings  Arc thermal performance value (ATPV): expressed using cal/cm2 to identify the incident energy level at which there is a 50% probability of sufficient heat transfer to cause the onset of a second-degree skin burn injury. 
   • Breakopen threshold energy (Ebt): expressed using cal/cm2 that identifies the incident energy level at which there is a 50% probability of the formation of holes or tears in the garment layer closest to the skin.

Jim Pollard is a member of several technical committees, including CSA Z462. He is the owner of Unlimited PPE in Stoney Creek, Ont., and can be reached at jim@unlimitedppe.com or (905) 573-0300.

Reprinted by permission of Canadian Occupational Safety © Thomson Reuters Canada Ltd., April/May 2015, Toronto, Ontario, 1-800-387-5164. Web: www.cos-mag.com.

Related Articles


Latest Articles


Changing Scene

  • Piloting New Ways to Make Homes More Energy-Efficient and Affordable

    Piloting New Ways to Make Homes More Energy-Efficient and Affordable

    October 22, 2024  Canada’s buildings sector is the third-largest contributor to greenhouse gas emissions across the country.  We must increase the scale and pace of retrofitting buildings across the country to make them more energy-efficient, increasing savings and reducing emissions. A federal investment totalling $4.3 million has been announced for five projects funded under the Greener Neighbourhoods Pilot Program (GNPP)… Read More…

  • Manitoba Restores 1:1 Apprenticeship Ratio

    Manitoba Restores 1:1 Apprenticeship Ratio

    October 24, 2024 Regulatory changes that restore the 1:1 apprentice-to-journeyperson ratio and modernize training programs will come into effect Oct. 30, Economic Development, Investment, Trade and Natural Resources Minister Jamie Moses announced today. “Restoring the 1:1 ratio supports safe and higher quality training for workers,” said Moses. “All Manitobans deserve to come home safely at… Read More…

  • RESA Power Significantly Expands Its Medium Voltage Power System Supply and Engineering Capability with the Acquisition of Prime Engineering Ltd.

    RESA Power Significantly Expands Its Medium Voltage Power System Supply and Engineering Capability with the Acquisition of Prime Engineering Ltd.

    October 21, 2024 RESA Power, LLC has announced the acquisition of Prime Engineering Ltd. Based in Victoria, British Columbia, Prime is a full-service electrical design, engineering, supply, and services business that has specialized in medium voltage electrical power and control systems, as well as providing electrical field services, since 2010. With the Prime acquisition, RESA Power significantly… Read More…

  • Hammond Power Solutions Appoints Elec-Tech Sales as New Representative in B.C.

    Hammond Power Solutions Appoints Elec-Tech Sales as New Representative in B.C.

    October 21, 2024 Hammond Power Solutions is pleased to announce the appointment of Elec-Tech Sales Ltd. as their new representative for British Columbia, Canada, effective October 15, 2024. For over 40 years Elec-Tech Sales has been representing leading electrical manufacturers in B.C. They have a strong presence with HPS channel partners as well as experience… Read More…