Smart Technology Leads the way for Energy Efficiency at Electric Utilities

Schneider

December 7, 2017

How are you maximizing grid efficiency? Reducing electricity network losses requires smart strategies that improve active and passive energy efficiency. By planning, measuring, and improving transmission and distribution (T&D) efficiency and installing digital technology that is more accurate and connected, electric utilities take a big step toward increasing energy efficiency and trimming operating costs.

In part one of this blog series, we’ve established why efficient operations are crucial for staying in compliance, integrating distributed energy resources (DER), and saving money. Now let’s take a closer look at how utilities and distribution system operators (DSOs) can modernize operations to accommodate regulations and reduce costs.

Advanced distribution management systems (ADMS) can be implemented for tasks such as estimating and minimizing losses, managing peak demand, and automated fault location, isolation, and service restoration. An ADMS simulates the impact on reliability of supply, losses, and voltage management, and algorithms calculate optimum configurations based on data that comes from sensors, smart meters, and a number of switch operations. Deploying a system like ADMS provides many benefits, including decreasing losses, improving voltage quality, and achieving an optimal voltage profile.

Distributed energy resources are straining utilities’ ability to maintain their contractually agreed upon voltage levels. DERs, which have variable energy outputs, are being injected into the grid and can cause the voltage to increase in one section of the grid while it decreases in another. Traditional voltage control tools are no longer adequate for managing these demands and fluctuations, so utilities and DSOs are deploying new solutions and sensors to finely tune the voltage control infrastructure to minimize technical losses and reduce costs. There are a , including smart sensors, virtual sensors, and remote terminal units (RTUs) to aid in this process.

A monitoring system for European-style networks where LV networks have three phases and a neutral wire can collect data such as substation and feeders’ daily load, voltage, and temperature profiles to provide a detailed analysis of MV/LV level performance data. This type of LV monitoring can accommodate more DER since it addresses problems such as load imbalance and works to decrease energy loss, which can improve substation output and reduce joules losses in cables.

Losses are assumed to range between 1,000 to 10,000 euros per MV/LV substation per year in European countries. Therefore, reducing losses is a top concern and there are many strategies for going about this, including adding smart energy meters and additional sensors that identify the source of losses and quantify them so that network operators can start energy efficiency improvements.

Utilities have made huge strides in meeting their energy efficiency goals by modernizing inefficient distribution transformers, which have a high potential for improvement. Transformer technology has gotten significantly better in recent years and now includes different transformers options that allow utilities to optimize OPEX and CAPEX.

These strategies and suggestions are just a jumping-off point. For a more in-depth look at how you can modernize your operations while decreasing your network distribution losses, don’t miss “Smart Distribution Utility Strategies that Maximize Grid Efficiency.”

Source: https://blog.schneider-electric.com/energy-management-energy-efficiency/2017/11/27/smart-technology-leads-way-energy-efficiency-electric-utilities/

Related Articles


Latest Articles


Changing Scene

  • Hammond Power Solutions Appoints Linda Nadeau Sanford as Western Regional Sales Manager

    Hammond Power Solutions Appoints Linda Nadeau Sanford as Western Regional Sales Manager

    May 12, 2025 Hammond Power Solutions (HPS), a leader in dry-type transformers and power quality solutions, is pleased to announce the appointment of Linda Nadeau Sanford as the new Western Regional Sales Manager. Linda will play a key part in driving sales and revenue across the Western Canada region. She will oversee territory management, advance… Read More…

  • Susanna Zagar, Ontario Energy Board CEO, Named EHRC’s 2025 Agent of Change

    Susanna Zagar, Ontario Energy Board CEO, Named EHRC’s 2025 Agent of Change

    May 12, 2025 Electricity Human Resources Canada (EHRC) is proud to announce Susanna Zagar (she/her), Chief Executive Officer of the Ontario Energy Board (OEB), as the recipient of the 2025 Agent of Change Award. This recognition celebrates Ms. Zagar’s remarkable leadership and commitment to diversity, equity and inclusion (DEI) in the electricity sector. Since stepping… Read More…

  • AD Reports Huge Jump in Member Sales Through Three Months of 2025

    AD Reports Huge Jump in Member Sales Through Three Months of 2025

    May 12, 2025 AD reports that member sales in the first three months of 2025 increased 23% to a record $24 billion across the group’s 14 divisions and three countries. AD welcomed over 550 new members in the first quarter through both organic growth and the IMARK Electrical merger. AD members also acquired another 10… Read More…

  • Legrand Introduces Wattstopper i3 Building Management Platform

    Legrand Introduces Wattstopper i3 Building Management Platform

    May 12, 2025 Legrand® has announced the launch of the Wattstopper i3 Platform, a next-generation lighting and building intelligence solution powered by KODE Labs, a global leader of advanced smart building technology.  The partnership positions Legrand to lead the lighting controls industry into a new era of unified experiences, seamless integrations, and data-driven control, making it easier… Read More…