Stay Ahead of Updated Fibre Optic Testing Standards, Ideal Networks Urges Installers

Updated Fibre Optic Testing

 

September 01 2016

The international standards to which fibre optic cabling and encircled flux compliant light sources are field-tested are changing. New ISO/IEC and ANSI/TIA standards will have a notable impact on the test equipment required by installers.
“The new encircled flux testing standards will slowly start to make their way into contracts and customer requirements,” says Tim Widdershoven, Global Marketing Manager for Ideal Networks. “Installers will need to obtain accurate, compliant measurements. So, to ensure a problem-free testing experience they must be equipped with the correct testing tools and equipment.”

The ISO/IEC 14763-3:2014 standard specifies systems and methods for the inspection and testing of installed optical fibre cabling designed in accordance with premises cabling standards while the ANSI/TIA-526-14 standard is applicable to the measurement of attenuation of installed fibre optic cabling using multimode fibre. The purpose of these standards, which are both due to be updated this year, is to ensure that regardless of which manufacturer’s test system is being used, all the different test systems report the same loss for the cable being tested.

“To stay ahead of the new testing requirements, installers should not delay in ensuring that the test cords that accompany their power meters and light sources are made with reference grade connectors,” explains Tim. “They must also understand which tools and methods will deliver compliant test results in varied scenarios, for example the differences that exist when using LED or VCSEL light sources.”

The most significant change is the addition of encircled flux testing which ensures that all fibre optic testers provide the same results when testing the same cable. To accomplish this, installers will need to add encircled flux launch cables to their existing inventory of fibre optic test equipment. Additionally, encircled flux testing does not allow VCSEL light sources thus requiring “upgrading” to LED light sources.

For fast and simple certification of high bandwidth single and multimode fibre optic cabling, including support for encircled flux testing, Ideal Networks says its FiberTEK III adapters can be used with the LanTEK III cable certifier. According to the company, the FiberTEK III adapters offer quick and easy Tier 1 certification which is also compliant with the new 2016 encircled flux fibre standards when equipped with encircled flux launch cords.

To help keep costs manageable, continues Ideal Networks, LanTEK III and FiberTEK III have been designed as a modular solution so that cable installers only need to pay for the components that they need.

“When combined, reference-grade connectors and cords, encircled flux compliant launches and clean connectors will provide the best possible testing experience resulting in fewer failed tests and less time spent troubleshooting,” says Tim. “However, technicians should also remember to clean the ports of test equipment and test cords every time they are used —if the end faces on connectors, launch cables and testers are not clean, these important test results will not be accurate.”


To support installers, Ideal Networks has published an article containing more detailed guidance on how to test fibre optic cable with encircled flux compliant light sources. Watch for it in the October 4 issue of Electrical Industry News Week.

Related Articles


Latest Articles

  • New STANDATA Interpretation & Variance: Use of Neutral Conductors in Consumer’s Service Reporting of Electrical Incidents

    New STANDATA Interpretation & Variance: Use of Neutral Conductors in Consumer’s Service Reporting of Electrical Incidents

    October 6, 2025 There are two new STANDATA releases for the province of Alberta: The purpose of these two releases is to clarify requirements for reporting electrical incidents in Alberta and to permit the use of underground service entrance cable (USEB) with a bare neutral conductor in underground installations at service entrance equipment. STANDATA variance… Read More…

  • BizEnergySaver Program Available in Toronto & Ottawa

    BizEnergySaver Program Available in Toronto & Ottawa

    October 6, 2025 Commercial buildings in Ottawa and Toronto’s Richview South area can receive direct installation and instant discounts on energy-saving equipment upgrades for lasting benefits. The Save on Energy BizEnergySaver program is designed to help industrial, commercial and institutional (ICI), and multi-residential building owners and operators make equipment improvements to reduce their energy consumption…. Read More…

  • Electrical Industry Day of Recognition – October 6, 2025: John’s Story

    Electrical Industry Day of Recognition – October 6, 2025: John’s Story

    October 6, 2025 The Electrical Injury Day of Recognition is sponsored by the Electrical Contractors Association of Alberta, the Canadian Electrical Contractors Association, the Electrical Contractors Association of British Columbia, and the National Electrical Trade Council. The Canadian electrical industry is calling on all tradespeople and those who benefit from them, to set aside October 6 as a day… Read More…

  • Research Report: Visible and Invisible Consequences of Electrical Injury

    Research Report: Visible and Invisible Consequences of Electrical Injury

    October 6, 2025 This report was produced by the Infrastructure Health & Safety Association (ISHA). You can find the report, as well as sources on their website. This report has been written by Dr. Manuel Gomez, director of the St. John’s Rehab Research Program at Sunnybrook Health Sciences Centre in Toronto. Electricity is an important… Read More…


Changing Scene

  • Ontario Takes Next Step in Bowmanville Hospital Expansion

    Ontario Takes Next Step in Bowmanville Hospital Expansion

    October 6, 2025 The Ontario government is marking a key milestone in delivering high-quality hospital care for families in Durham Region by issuing a Request for Proposals (RFP) to select the team that will lead the expansion and revitalization of Lakeridge Health’s Bowmanville Hospital. This project will mark one of the largest redevelopments at Lakeridge… Read More…

  • Nova Scotia Takes Further Steps to Unlock Development in Halifax

    Nova Scotia Takes Further Steps to Unlock Development in Halifax

    October 6, 2025 Nova Scotia is taking more action to support housing growth in Halifax Regional Municipality (HRM), issuing new orders and moving policies forward. The measures include Municipal Affairs Minister John Lohr designating HRM as an interim planning area. Under this order, new minimum planning requirements for HRM take effect immediately. The designation also enables… Read More…

  • E.B. Horsman & Son Announces Stephen Murray as New Calgary Branch Manager

    E.B. Horsman & Son Announces Stephen Murray as New Calgary Branch Manager

    October 6, 2025 EB Horsman & Son is pleased to announce the appointment of Stephen Murray as Branch Manager of its Calgary location, effective Tuesday, September 3, 2025. Stephen Murray brings over two decades of experience in the industrial automation sector, where he has built a strong reputation for driving growth, expanding market presence, and… Read More…

  • E.B. Horsman & Son Announces Maxim Laberge as New Process Instrumentation Manager

    E.B. Horsman & Son Announces Maxim Laberge as New Process Instrumentation Manager

    October 6, 2025 EB Horsman is excited to welcome Maxim Laberge as its new Process Instrumentation Manager. Maxim Laberge brings over 25 years of experience in electrical, instrumentation, and control systems, with a proven record in business development, client engagement, and strategic project leadership. He is known for his consultative approach, combining technical insight with… Read More…