Working among the electrical components in an enclosure comes with inherent risks. The power in any one enclosure can range from 2kw up to 200kw depending on the power density. One of the most common and dangerous risks is an arc flash (or flashover).

When an explosive release of energy erupts from a phase-to-phase or phase-to-ground arc fault, the results range from devastating to deadly. This air to ground electrical explosion is a critical concern.

The destructive force of an arc flash

The dangers from an arc flash are all too well known. When metal expands and vaporizes at the fault, it causes extreme heating of the air, upwards of 10,000°C/18,032°F. The concussive pressure wave can knock personnel off their feet; the ultraviolet light flash can cause blindness; the sound blast, deafness; and the molten metal and heat can cause second and third degree burns. The specific death toll has been estimated to be up to 1-2 people every day worldwide.

An arc flash can result from unsafe work procedures, accidental contact, or more systemic problems such as corrosion of components and connections or insulation failure. Arc flash prevention should be incorporated into any application from the beginning of the design process.

Minimizing arc flash exposure

Design and retrofit approaches can limit exposure by using components installed outside the enclosure to permit qualified personnel in personal protective equipment (PPE) to service equipment inside without opening the enclosure door. Interface flaps and window kits permit data retrieval, equipment monitoring or routine maintenance to be performed from outside. Collapsible fold down shelves be raised for use with laptops and monitoring equipment. External data pockets can hold wiring diagrams, operation manuals and other documents.

Arc flash protection

Sometimes components must be accessed from inside the enclosure. For example, Rittal’s arc flash solution keeps high and low voltage equipment within the confines of their own respective enclosures. Low voltage enclosures house equipment that is used for programming, data acquisition and system adjustment.

High voltage components are isolated within their own disconnect enclosure, while line side power is segregated within the power isolation enclosure. A partition wall acts as a barrier to high voltage line side power. An interlocking door system ensures that the high voltage enclosure cannot be opened while the disconnect switch is in “ON” position.

For additional safety, all interlocked doors and master door must be closed in order to re-energize the enclosure. This removes potential for accidental contact with the inline power when the disconnect enclosure is put in a safe power-off position, and locked and tagged out.

Minimizing exposure to line side power can help protect personnel from accidents. A qualified person wearing PPE and following appropriate safe work practices can perform visual inspections and tasks, such as diagnosis, testing, troubleshooting and voltage measurement with the door open even when the main enclosure is energized.

Safety is always your priority, so download Rittal’s Arc Flash and How to Prevent it free whitepaper for the first step towards arc flash prevention: http://info.rittalenclosures.com/arch-flash-lp-0.

Steve Sullivan is a training manager with Rittal. This article was first published online as a blog: http://blog.rittalenclosures.com/blog/author/steve-sullivan-training-manager.

 

Related Articles


Latest Articles


Changing Scene

  • Save the Date: Ontario Apprenticeship Summit 2026 – November 4, 2026

    Save the Date: Ontario Apprenticeship Summit 2026 – November 4, 2026

    July 6, 2026 Skilled Trades Ontario (STO) is pleased to announce that the third annual Ontario Apprenticeship Summit will take place during National Skilled Trades and Technology Week. Industry partners, skilled trades professionals, and apprentices are invited to attend the Toronto Congress Centre on Wednesday, November 4, 2026. The Ontario Apprenticeship Summit 2026 is focused… Read More…

  • Fort McMurray Apprentice Electrician to Represent Canada at Skilled Canada National Competition

    Fort McMurray Apprentice Electrician to Represent Canada at Skilled Canada National Competition

    July 6, 2026 In recognition of World Youth Skills Day, which underscores the vital role of skills development among young people, Skills/Compétences Canada (SCC) is proud to officially announce the 31 talented members of WorldSkills Team Canada 2026.These young competitors will begin their training to prepare for the 48th WorldSkills Competition, in Shanghai, China, which will be held… Read More…

  • Westburne Celebrates 100 Years with Brandon Trade Show

    Westburne Celebrates 100 Years with Brandon Trade Show

    July 6, 2026 Recently, Westburne hosted over 200 guests and over 60 partners and suppliers at their Brandon Trade Show to celebrate 100 years of Westburne. “Westburne’s annual Midwest Tradeshow welcomed more than 220 attendees in Brandon this year, including representatives from over 60 partner businesses and suppliers. Taking place annually for over 15 years,… Read More…

  • B.C. Expands Energy Efficiency Program to Provide No-Cost Retrofits to Homeowners, Tenants

    B.C. Expands Energy Efficiency Program to Provide No-Cost Retrofits to Homeowners, Tenants

    July 3, 2026 Together with BC Hydro, FortisBC and Natural Resources Canada, the Province is supporting families with lower incomes to save money on their utility costs through home-energy improvements.  “We are taking action to help people lower their utility bills by expanding our home energy-efficiency programming for lower-income families,” said Adrian Dix, B.C.’s Minister… Read More…