Multi-Conductor Riser-CMR Shielded Security and Alarm Cable

Belden Shielded Security Cable

Nov 19, 2020

Belden Security and Alarm Cable, Multi-Conductor Riser-CMR Shielded, Series: 5306FE, 300 VAC, 3.5 A, 8 Conductors, Bare Stranded Copper Conductor, 18 AWG Conductor, 6.223 mm Outside Dia, 500 ft Length, 7×26 Strands, 21.3265 Ohm, Polypropylene Insulation, PVC, Gray, -20 to 75 deg C.

 

 

 

 

 

 

 

 

• 0.203 mm insulation wall thickness
• 0.457 mm jacket wall thickness
• 859.392 N maximum recommended pulling tension
• 63.5 mm minimum bend radius/minor axis
• 88.587 pf/ft nominal conductor to conductor capacitance
• 159.129 pf/ft nominal conductor to other conductor and shield capacitance
• 21.36 Ohm/km nominal conductor DC resistance capacitance
• 50.035 Ohm/m at 20 deg C nominal outer shield DC resistance
• 18 AWG, 7×26 bare copper drain wire
• Black, red, white, green, brown, blue, orange and yellow overall cabling color code
• Beldfoil® aluminum foil polyester tape with shorting fold shield and PVC jacket with ripcord
• Crate reel put-up

Related Articles


Latest Articles


Changing Scene

  • CAF-FCA Welcomes Federal Apprenticeship Investments, Urges Focus on Implementation

    CAF-FCA Welcomes Federal Apprenticeship Investments, Urges Focus on Implementation

    May 1, 2026 CAF-FCA welcomes the federal government’s strong focus on skilled trades in the 2026 Spring Economic Update, including new investments in apprenticeship pathways, financial supports, and employer incentives. These measures reflect long standing priorities advanced by employers and partners across the country. The Canadian Apprenticeship Forum (CAF-FCA) welcomes the Government of Canada’s renewed Read More…

  • ECABC Announces 2026 Hall of Fame Inductees

    ECABC Announces 2026 Hall of Fame Inductees

    April 30, 2026 ECABC is proud to announce that Bill Strain and Rob Tate will be inducted into the ECABC Electrical Hall of Fame this June. Bill and Rob have devoted their careers to the electrical contracting industry in British Columbia. Induction into the Electrical Hall of Fame is the highest honour the Association can Read More…

  • Nexans Initiates Copper Mark Recertification for Montreal Site

    Nexans Initiates Copper Mark Recertification for Montreal Site

    April 27, 2026 Nexans Canada Inc. has initiated the Copper Mark recertification process for its site located at 460 Durocher Avenue in Montreal. As part of this process, an independent external assessment of the site is scheduled for April 22–24, 2026. Copper Mark is an independent assurance framework designed to assess the responsible practices of industrial sites against recognized Read More…

  • Fort Frances Memorial Sports Centre Adding Solar as Part of GICB Program

    Fort Frances Memorial Sports Centre Adding Solar as Part of GICB Program

    April 27, 2026 The Fort Frances Memorial Sports Centre will generate solar energy following an investment of $589,762 from the federal government through the Green and Inclusive Community Buildings (GICB) program. This funding will reduce greenhouse gas emissions and annual electricity costs for the facility. A rooftop solar generation system will convert solar energy into Read More…